Performance Data @ AHRI Standard Conditions—Cooling
Model Numbers
Outdoor
Indoor
Unit
Coil and/or
14AJM
Air Handler
Rev.
RHLL-HM4824(RCSL-H*4824)
6/14/12
RHPL-HM4824(RCSL-H*4824)
48
RHPN-HM4824(RCSN-H*4824)
RCFL-H*4821+RXMD-C04 ➀
RCFL-A*4821(RGFE-09?ZCM?)
RCFL-A*4821(RGFE-10?ZCM?)
RCFL-A*4821(RGFG-09?ZCM?)
RCFL-A*4821(RGFG-10?ZCM?)
RCFL-A*4821(RGGE-09?ZCM?)
RCFL-A*4821(RGGE-10?ZCM?)
RCFL-A*4821(RGLE-07?BRQ?)
RCFL-A*4821(RGLE-10?BRM?)
RCFL-A*4821(RGLT-07?AMK?)
RCFL-A*4821(RGLT-07?BRQ?)
RCFL-A*4821(RGLT-10?BRM?)
RCFL-A*4821(RGPE-07?BRQ?)
RCFL-A*4821(RGPE-10?BRM?)
RCFL-A*4821(RGPT-07?AMK?)
RCFL-A*4821(RGPT-07?BRQ?)
RCFL-A*4821(RGPT-10?BRM?)
RCFL-A*4821(RGRM-09?ZAJ?)
RCFL-A*4821(RGRM-10?ZAJ?)
RCFL-A*4821(RGTM-07?RBG?)
RCFL-A*4821(RGTM-09?ZAJ?)
RCFL-A*4821(RHWB-04WMX36A)
RCFL-A*4821(RHWB-06WMX48A)
49
RCFL-A*4821(ROCA-070E04)
RCFL-A*4821(ROLA-070E04)
RCFL-A*4821(ROLA-115E05)
RCFL-A*4821+RXMD-C04
RCFL-A*4824(RGFE-09?ZCM?)
RCFL-A*4824(RGFE-10?ZCM?)
RCFL-A*4824(RGFE-12?RCM?)
RCFL-A*4824(RGFG-09?ZCM?)
RCFL-A*4824(RGFG-10?ZCM?)
RCFL-A*4824(RGFG-12?RCM?)
RCFL-A*4824(RGGE-09?ZCM?)
RCFL-A*4824(RGGE-10?ZCM?)
RCFL-A*4824(RGGE-12?RCM?)
RCFL-A*4824(RGJF-09?ZCM?)
RCFL-A*4824(RGJF-10?ZCM?)
RCFL-A*4824(RGJF-12?RCM?)
RCFL-A*4824(RGLE-07?BRQ?)
RCFL-A*4824(RGLE-10?BRM?)
RCFL-A*4824(RGLE-12?ARM?)
RCFL-A*4824(RGLT-07?BRQ?)
RCFL-A*4824(RGLT-10?BRM?)
RCFL-A*4824(RGLT-12?ARM?)
RCFL-A*4824(RGPE-07?BRQ?)
RCFL-A*4824(RGPE-10?BRM?)
➀ Highest sales volume tested combination required by D.O.E. test procedures.
80°F [26.5°C] DB/67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Total
Net
Capacity
Sensible
BTU/H [kW]
BTU/H [kW]
49,500 [14.5]
35,300 [10.3]
49,500 [14.5]
35,300 [10.3]
52,000 [15.2]
38,000 [11.1]
46,500 [13.6]
33,000 [9.7]
45,500 [13.3]
31,000 [9.1]
45,500 [13.3]
31,200 [9.1]
45,500 [13.3]
31,000 [9.1]
45,500 [13.3]
31,000 [9.1]
45,500 [13.3]
31,200 [9.1]
45,500 [13.3]
31,000 [9.1]
46,000 [13.5]
31,400 [9.2]
46,000 [13.5]
31,400 [9.2]
45,500 [13.3]
30,600 [9.0]
46,000 [13.5]
31,600 [9.3]
46,000 [13.5]
31,400 [9.2]
46,000 [13.5]
31,400 [9.2]
46,500 [13.6]
32,800 [9.6]
45,000 [13.2]
30,200 [8.8]
46,000 [13.5]
31,800 [9.3]
46,000 [13.5]
31,400 [9.2]
45,500 [13.3]
31,000 [9.1]
45,500 [13.3]
31,200 [9.1]
45,500 [13.3]
30,600 [9.0]
45,500 [13.3]
31,200 [9.1]
45,500 [13.3]
30,300 [8.9]
45,000 [13.2]
29,800 [8.7]
45,500 [13.3]
30,800 [9.0]
45,500 [13.3]
31,000 [9.1]
46,000 [13.5]
31,200 [9.1]
46,500 [13.6]
33,200 [9.7]
45,500 [13.3]
31,000 [9.1]
45,500 [13.3]
31,200 [9.1]
46,000 [13.5]
31,800 [9.3]
45,500 [13.3]
31,000 [9.1]
45,500 [13.3]
31,000 [9.1]
46,000 [13.5]
31,800 [9.3]
45,500 [13.3]
31,200 [9.1]
45,500 [13.3]
31,000 [9.1]
46,000 [13.5]
31,200 [9.1]
45,500 [13.3]
30,900 [9.1]
45,500 [13.3]
30,950 [9.1]
46,000 [13.5]
31,150 [9.1]
46,000 [13.5]
31,400 [9.2]
46,000 [13.5]
31,400 [9.2]
46,000 [13.5]
31,800 [9.3]
46,000 [13.5]
31,600 [9.3]
46,000 [13.5]
31,400 [9.2]
46,000 [13.5]
31,000 [9.1]
46,000 [13.5]
31,400 [9.2]
46,500 [13.6]
32,800 [9.6]
Net
Latent
EER
SEER
BTU/H [kW]
14,200 [4.2]
13.00
15.50
14,200 [4.2]
13.00
15.50
14,000 [4.1]
13.00
16.00
13,300 [3.9]
12.00
14.50
14,600 [4.3]
12.00
14.50
14,400 [4.2]
12.00
14.50
14,600 [4.3]
12.00
14.50
14,600 [4.3]
12.00
14.50
14,600 [4.3]
12.50
15.00
14,600 [4.3]
12.00
14.50
14,600 [4.3]
12.50
15.10
14,600 [4.3]
13.00
15.50
15,000 [4.4]
13.00
15.50
14,400 [4.2]
12.50
15.10
14,600 [4.3]
12.50
15.10
14,600 [4.3]
12.50
15.10
13,600 [4.0]
12.50
15.10
15,000 [4.4]
12.00
14.50
14,400 [4.2]
13.00
15.50
14,600 [4.3]
13.00
15.50
14,600 [4.3]
12.00
14.50
14,400 [4.2]
12.00
14.50
15,000 [4.4]
12.50
15.10
14,600 [4.3]
12.50
15.00
15,200 [4.5]
12.50
15.10
15,200 [4.5]
12.50
15.00
14,600 [4.3]
12.00
14.50
14,700 [4.3]
12.50
15.10
14,600 [4.3]
12.50
15.10
13,300 [3.9]
12.00
14.50
14,600 [4.3]
12.00
14.50
14,400 [4.2]
12.00
14.50
14,200 [4.2]
12.50
15.10
14,600 [4.3]
12.00
14.50
14,600 [4.3]
12.00
14.50
14,200 [4.2]
12.50
15.10
14,600 [4.3]
12.50
15.00
14,600 [4.3]
12.00
14.50
14,700 [4.3]
12.50
15.10
14,600 [4.3]
12.50
15.10
14,550 [4.3]
12.00
14.50
14,850 [4.4]
12.50
15.50
14,600 [4.3]
12.50
15.10
14,600 [4.3]
13.00
15.50
14,400 [4.2]
13.00
15.50
14,400 [4.2]
12.50
15.10
14,600 [4.3]
12.50
15.10
14,900 [4.4]
13.00
15.50
14,600 [4.3]
12.50
15.10
13,600 [4.0]
12.50
15.10
[ ] Designates Metric Conversions
Performance Data
Air
14AJM Series
Sound
Indoor
Rating
CFM [L/s]
dB
77
1,625 [767]
77
1,625 [767]
77
1,600 [755]
77
1,600 [755]
77
1,400 [661]
77
1,425 [672]
77
1,400 [661]
77
1,400 [661]
77
1,400 [661]
77
1,400 [661]
77
1,400 [661]
77
1,400 [661]
77
1,325 [625]
77
1,425 [672]
77
1,400 [661]
77
1,400 [661]
77
1,550 [731]
77
1,325 [625]
77
1,425 [672]
77
1,400 [661]
77
1,400 [661]
77
1,425 [672]
77
1,325 [625]
77
1,400 [661]
77
1,300 [613]
77
1,300 [613]
77
1,400 [661]
77
1,375 [649]
77
1,400 [661]
77
1,600 [755]
77
1,400 [661]
77
1,425 [672]
77
1,450 [684]
77
1,400 [661]
77
1,400 [661]
77
1,450 [684]
77
1,400 [661]
77
1,400 [661]
77
1,375 [649]
77
1,400 [661]
77
1,400 [661]
77
1,375 [649]
77
1,400 [661]
77
1,400 [661]
77
1,425 [672]
77
1,425 [672]
77
1,400 [661]
77
1,350 [637]
77
1,400 [661]
77
1,550 [731]