Inspecting Burner; Cleaning And Maintenance - Comfort Glow CGN20TB Owner's Operation And Installation Manual

Blue flame vent-free natural gas heater heater sizes: 20,000 btu/hr thermostat and 30,000 btu/hr thermostat model heaters
Table of Contents

Advertisement

OWNER'S
MANUAL
INSPECTING
BURNER
Check pilot flame pattern and burner flame
pattern often.
PILOT FLAME
PATTERN
Figure 18 shows a correct pilot flame pat-
urn. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
If pilot flame pattern
is incorrect,
as shown
in Figure 19.
• turn heater off (see To Turn OffGas
to
Appliance,
page 12).
• seeTroubleshooting,
pagesl4throughl6.
Pilot Burner
Figure 18- Correct Pilot Flame Pattern
Thermocouple
Pilot Burner
Figure 19 - Incorrect Pilot Flame Pattern
BURNER
FLAME PATrERN
Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.
WARNING: If yellow tipping
occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions
at bottom of this
page.
NOTICE: Do not mistake orange
flames with yellow tipping. Dirt
or other fine particles enter the
heater and burn causing brief
patches of orange flame.
If burner flame pattern is incorrect, as shown
in Figure 21
• turn heater off(see To Turn OffGas to
Appliance, page 12).
• seeTroubleshooting, pages 14through 16.
CLEANING
AND
MAINTENANCE
• 1=WARNING: Tum off heater
and let cool before cleaning.
CAUTION:
You must keep
control areas, burner, and circu-
lating air passageways of heater
clean.
Inspect
these areas of
heater before each use. Have
heater inspected yearly by a qualb
fled service person.Heater
may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.
ODS/PILOT
AND BURNER
• Use a vacuum cleaner, pressurized air,
or small, soft bristled brush to clean.
CABINET
Air Passageways
• Use a vacuum cleaner or pressurized air
to clean.
CORRECT
FLAME PATTERN
AT HIGH POSITION
Exterior
• Use a soft cloth dampened with a mild
_,,.=,,_
soap and water mixture. Wipe the cabi-
net to remove dust.
Figure 20- Correct Burner Flame Pattern
Yellow
INCORRECT
FLAME PAI"rERN
AT HIGH POSmON
Figure 21 - Incorrect Burner Flame Pattern