GE ZET1 Installation Instructions Manual page 5

30" built-in wall oven
Table of Contents

Advertisement

Installation Instructions
CutoUtutfOr
Single Built-In Oven
Width
28 1/2" Min.
28 5/8" Max,
(72.4 to
72.7 cm)
-->"
• F_ Opening
Between
Inside Walls
Must Be
At Least
28 1/2"
Wide
Allow 11/16" --_-_
(1,76 cm) for
overlap of oven
over side edges
of cutout
(63.3 c _
Allow 1" (2.6 cm)
minimum for
overlap of oven
Allow a minimum
top and 1V4"
of 21" (63.3 cm) for
(3.2 cm) overlap
clearance to adjacent
of oven bottom
corners, drawers,
of cutout
walls, etc. when
door is open
Cabinet
Width
30" (76.2 cm)
Cabinet Width
Recommended
Minimum
Junction Box
Cutout Location
/
Location
from
Floor
22" (55.9 cm)
to Bottom of
Junction Box
Cutout Depth
Cutout Width
Cutout Height
30" (76.2 cm)
32 1/2" (82.6 cm)
23 1/2" (59.7 cm) Min.
28 1/2" (72.4 cm) Min.
28 5/8" (72.7 cm) Max.
27 1/4" (69.2 cm) Min.
27 5/16" (69.2 cm) Max.
NOTE: If the cabinet
does
not have a front
frame and
the sides are less than 3/4"
(1.9 cm) thick, shim both
sides equally to establish
the cutout width.
If the cabinet does not have a solid bottom,
two braces or runners
must be installed
level with the bottom of the cutout to
support
the weight of the oven. For single
ovens, the runners and braces must
support
175 Ibs. (79 kg).
NOTE: If marks, blemishes
or the
cutout opening
are visible above the
installed oven, it may be necessary
to
add wood shims under the runners and
front
trim until the marks or opening
are covered.
Suitable
Bracing
to Support
Runners
--
21 518"
(54.9 cm)_
Over Centerline
of Cabinet
--
Install a
solid bottom
or2" x4"
(6cmxlOcm)
or equivalent
runners level
with bottom
of cutout
The solid bottom or runners
must be level
with the bottom of the cutout, or the bottom
trim may not install correctly
and then
interfere
with the door opening.
This oven is not approved for
stackable or side by side installation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zet2