Undetermined Problems - eMachines D620 Service Manual

Service guide
Hide thumbs Also See for D620:
Table of Contents

Advertisement

Undetermined Problems

The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect,
whether a short circuit is suspected, or whether the system is inoperative.
NOTE: Verify that all attached devices are supported by the computer.
NOTE: Verify that the power supply being used at the time of the failure is operating correctly. (See "Power
System Check" on page 89.)
Follow procedures below to isolate the failing FRU. Do not isolate non-defective FRU.
1.
Power off the computer.
2.
Visually check them for damage. If any problems are found, replace the FRU.
3.
Remove or disconnect all of the following devices:
Non-Acer devices
Printer, mouse, and other external devices
Battery pack
Hard disk drive
DIMM
CD/DVD-ROM drive
PC cards
4.
Power on the computer.
5.
Determine if the problem has been resolved.
6.
If the problem does not recur, reconnect the removed devices one at a time until you find the failed FRU.
7.
If the problem persists, replace the following FRU one at a time. Do not replace a non-defective FRU.
System board
LCD assembly
Chapter 4
103

Hide quick links:

Advertisement

Table of Contents
loading