ENT
Push this key to accept data entry.
M. in
In the manual receive mode or search mode, push the [FUNC] key, and then push this key
to enter the frequency into memory.
1-6
Computer control
Connect the AR-ONE to the serial port of a computer using an RS-232C serial cable
terminated in a 9-pin male connector. The RS-232C parameters may be defined using the
CONFIG menu. Baud rates (transfer speed) set to either 4800 or 9600 bps. Since there are
two independent RS-232C port with the AR-ONE, it is possible to set an 'address' to
facilitate connection of up to 99 AR-ONE to a single PC.
The RS-232C parameters are as follows:
Baud Rate:
De-limiter:
Data bit:
Stop bit:
Parity:
X parameter: ON
1-7 IF output and Spectrum Display Unit (SDU5500, SDU5600 )
The rear panel has a 10.7 MHz IF output designed to drive the optional SDU5500 or
SDU5600 Spectrum Display Unit. The SDU5500 or SDU5600 provides an excellent tool for
locating elusive transmission with a PEAK capability to 'freeze' the briefest of transmissions
for later measurement of frequency and level after the event.
(Note: The IF output frequency is selectable in the CONFIG menu. (10.7 MHz or 455KHz).
2 Getting started
2-1 Making the AR-ONE ready for operation
2-1-1 LCD (Liquid Crystal Display)
All relevant operational information is provided via the LCD. The LCD contrast is
adjustable.
4800 or 9600 bps
CR, LF
8 bit
2 bit
None
16