For Your Records and Warranty
Assistance
Model Name: _____________________
Catalog/Model No.: ________________
Serial No.: ________________________
Date Purchased: ___________________
Where Purchased: _________________
For reference also attach your receipt or a
copy of your receipt to the manual.
Hunter Fan Company
42704-01 • 01/29/07

Advertisement

Table of Contents
loading

Summary of Contents for Hunter Type C

  • Page 1 For Your Records and Warranty Assistance Model Name: _____________________ Catalog/Model No.: ________________ Serial No.: ________________________ Date Purchased: ___________________ Where Purchased: _________________ For reference also attach your receipt or a copy of your receipt to the manual. Hunter Fan Company 42704-01 • 01/29/07...
  • Page 2: Table Of Contents

    Before installing your fan, for your records and warranty assistance, record information from the carton and Hunter nameplate label (located on the top of the fan motor housing). Th ese installation instructions are for a Hunter Type “ C “ Fan.
  • Page 3: Optional Accessories

    Understanding Mounting Hunter’s patented mounting system provides you maximum ease in installing your fan. Th is fan was designed to be mounted only on fl at ceilings and can be used only on ceilings no less than 9 feet high.
  • Page 4: Getting Ready

    • Drill holes for and install wood screws. • Identify and connect electrical wires. • Lift 40 pounds. If you need help installing the fan, your Hunter fan dealer can direct you to a licensed installer or electrician. Gathering the Tools You will need the following tools for installing the fan: •...
  • Page 5: Pre-Installation

    (walls, posts, etc.) should be within 24” of the tips of the blades (see Fig. 1). Your Hunter fan comes with the proper hardware to hang the fan from a 9 foot ceiling so the fan blades will be 17 1/4” from the ceiling and approximately 7 feet from the fl oor (see Fig. 1).
  • Page 6: Installing Ceiling Hardware

    3/8” wrench to install the (2) 3 1/2” lag bolts to secure the U-bracket to the joist (see Fig. 2). Exploded View Installed View Cross Brace Rubber Bushing Ceiling and Pin Outlet U-Bracket Lag Bolt Fig. 2 3 1/2” Lag Bolt Hunter Fan Company 42704-01 • 01/29/07...
  • Page 7: Hanging The Fan

    NOTE: Some of the pipe threads may still be visible. 4. Slide the canopy down over the hanging pipe (see Fig. 5). Wires Hanger Pipe Motor Housing Motor Set Screw Housing Fig. 3 Fig. 4 Canopy Fig. 5 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 8 10. Lift the fan by the motor housing, hook the hanger bracket assembly onto the rubber bushing and pin. Make sure both ends of the pin are outside the hanger bracket assembly (see Fig 8). Rubber Bushing Hanger and Pin Bracket Assembly Fig. 8 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 9: Wiring The Fan

    7. Spread the wires apart, with the grounded Fig. 10 wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box. Hunter Fan Company 42704-01 • 01/29/07...
  • Page 10: Installing The Canopy

    1. Partially install the fi llister head #8-32 set screw. 2.. Slide canopy up close to ceiling. 3. Tighten the canopy fi llister head #8-32 set screw (see Fig. 11). Canopy Screw, Fillister Head #8-32 Fig. 11 Screw, Fillister Head #8-32 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 11: Lubrication

    Original fan once it is installed. Should you move your fan to another location, it is a good idea to check the oil reservoir. Hunter has developed an accessory ‘Original Relocation Kit’ that includes all mounting hardware and a fresh tube of oil for this reason.
  • Page 12: Fan Blade Assembly

    4. Before tightening the blade assembly screw, slightly turn blade assembly while hand tightening the set screw. 5. Tighten the blade assemble screw with pliers or adjustable wrench. Blade Counter Sink Blade Assembly Adapt Air Screw Blade Shaft Fig. 14 Fig. 15 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 13: Installing Bulb And Globe

    NOTE: Do not overtighten thumb screws, this can cause globe to crack. 5. Tighten the locking nut to keep thumb screw from loosening (see Fig. 17). 6. Turn on the power at the main junction box. Th umb Screw w/ Locking Nut Globe Fig. 17 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 14: Operation And Care

    1. Move the directional lever all the way to the left side for down draft (see Fig. 19). 2. Move the directional lever all the way to the right side for up draft (see Fig. 19). DOWN Pull Chain Directional Lever Fig. 19 Breakaway Connector Fig. 18 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 15: Troubleshooting Guide

    1. If your fan wobbles when operating, use the enclosed balancing kit and instructions to balance the fan. If you need parts or service assistance, please call 888-830-1326 or visit us at our WEB site at http://www.hunterfan.com. Hunter Fan Company 2500 Frisco Avenue Memphis, Tennessee 38114 Hunter Fan Company 42704-01 • 01/29/07...
  • Page 16 Notes Hunter Fan Company 42704-01 • 01/29/07...
  • Page 17: Hunter Fan Co

    HUNTER FAN COMPANY 2 5 0 0 F R I S C O A V E N U E M E M P H I S , T N 3 8 1 1 4 ©2007 HUNTER FAN CO.™...