Alarm Setting - JVC VN-V686UAPI Manual

Table of Contents

Advertisement

Setting MPEG-4 Priority Setting for VN-V686
Format /api/param?encode(2).priority=data
Example /api/param?encode(2).priority=motion
Example of response encode(2).priority&202 Accepted(encode(2).status=save)
Interpretation Change priority of MPEG-4. Specify "motion" or "quality". To keep frame rate, select "motion". To
keep image quality, select "quality".
The change is saved by the API, encode(2).status=save. If the change is not saved, the setting is restored by reboot.
Allowed users admin, operator

6.4. Alarm Setting

The APIs below are related to alarm setting. These are equivalent to the features on the Alarm page of the WEB
setting page. Refer to the instruction manual for details on the Alarm page.
Getting On/Off of Alarm Action from VN-V686
Format /api/param?application.event(Number).status
Example When Getting the on/off status of alarm action No. 1
/api/param?application.event(1).status
Example of response application.event(1).status=on&200 OK
Interpretation Acquire the on/off status of the alarm action for the specified alarm action number. 5 alarm actions
and 1 periodic FTP assigned to No.6 are available, so alarm action number can be 1 to 6. Note that alarm numbers are
different from the alarm input pin numbers. Either on or off is returned.
Allowed users admin, operator
Setting On/Off of Alarm Action, or Enabling Changes to Alarm Action for
VN-V686
Format /api/param?application.event(Number).status=data
Example When setting alarm action No. 1 to off
/api/param?application.event(1).status=off
Example of response application.event(1).status&200 OK
Interpretation Set the alarm action of the specified alarm action number to on/off, or enable changes to the alarm
action. 5 alarm actions and 1 periodic FTP assigned to No.6 are available, so alarm action number can be 1 to 6. Note
that alarm numbers are different from the alarm input pin numbers. Either on or off will be returned.
Specify "on", "off" or "restart". By "restart", changes to alarm action and alarm trigger are enabled. By "on" after
"restart", the alarm action starts working with the changed settings. If "restart" is not set after changes to alarm action
and alarm trigger, APIs to get settings of alarm action and alarm trigger return previous values.