High Limit Switch Removal And Replacement; Service - Kenmore 153.318020 Owner's Manual

2.5 gallon point of use water heater
Table of Contents

Advertisement

water inlet a nd outlet, open t henearest hot w ater tap and follow
filling instructions.
Improper
installation
and use may result
in property
damage,
• Fill tank with water before operation.
Never use this water heater unless it is completely
full of water. To
prevent damage
to the tank and heating element,
the tank must be
filled with water. Water must flow from the hot water faucet before
turning "ON" power. The manufacturer
will not warrant
any elements
damaged
by failure to follow instructions.
15. Check element for water leaks. If leakage occurs, tighten element.
If necessary
drain tank before repeating
Steps 7 and 8, remove
element and reposition gasket. Then repeat Steps 10 through 15.
16.Replace
the two spade connectors
on element
into their original
positions.
I7. Replace the mounting
bracket with the center rise facing outward
and the screw hole up, see Figure 10.
18.Replace
the insulation
and front panel, lining up the three tabs at
the top with the slots in the casing.
19. Replace the retaining screw and the temperature
knob.
20.Plug heater into electrical
outlet.
MOUNTING BRACKET
P D
PERSONNEL
coNSE oTERs
ANOOE
I
ELEMENT
ELEMENT
FLANGE
FIGURE 10.
GROUND
WIRES
TO REMOVE
AND REPLACE
ANODE:
I. Follow steps 1-8 of the Element Cleaning/Replacement
section.
2. Using a 7mm wrench,
remove
the nut securing
the anode.
3. Unscrew
and remove anode.
4. Screw in the new anode and secure with the retaining
nut.
5. Follow
instructions
for replacing
the element
in "ELEMENT
CLEANING/REPLACEMENT."
HIGH LIMIT SWITCH REMOVAL AND REPLACEMENT
1.
2.
3.
4.
Turn
off and unplug
the heater
from the electrical
outlet.
Remove
the front
panel,
see the "REMOVING
THE FRONT
PANEL"
section
in this manual.
Remove
the insulation
pad.
Remove
personnel
barrier.
Remove
the four wires connected
to the switch,
taking
care
to note the original
placement
of each wire.
Using
a 7mm
wrench,
remove
the nuts
securing
the high
limit
switch
to the tank
enough
to rotate
the switch
90 °
counterclockwise
and slide
it out from beneath
the bracket.
It is not necessary
to remove
the nuts completely.
Place
the new switch
beneath
the bracket
and rotate
it 90 °
clockwise.
NOTE:
The taller
spade
terminal
will be on the right
side.
BLACK WIRE__WHITE
WIRE
BROWN WIRE
_,J
BLUE WIRE
FIGURE 11.
6. Replace
and tighten
the nuts so the high limit switch
is firmly
in contact
with
the tank surface.
7. Replace
the four wires,
taking
care
that they
are replaced
into their
original
positions
and tighten
screws.
8. Replace
personnel
barrier;
replace
insulation
block
and the
front
panel.
SERVICE
If a condition
persists
or you are uncertain
about
the operation
of the water
heater
contact
Sears
Repair
Services.
If you are not thoroughly
familiar
with your water heater and safety
practices,
contact
Sears
Repair
Services
at 1-8O0-4-MY-HOME
(1-800-469-4663).
19