Thermostat Removal/Replacement; Element Cleaning/Replacement - Kenmore 153.316050 Use & Care Manual

Compact electric water heater 10 gallon,19 gallon short,19.9 gallon tall,30 gallon,19.9 gallon tall, 240 v.
Hide thumbs Also See for 153.316050:
Table of Contents

Advertisement

Thermostat Removal/Replacement

1. Turn "OFF" the electrical power to the water heater at the
junction box.
HAZARD OF ELECTRICAL SHOCK! Before removing any
access panels or servicing the water heater, make sure the
electrical supply to the water heater is turned "OFF". Failure to
do this could result in DEATH, SERIOUS BODILY INJURY OR
PROPERTY DAMAGE.
2. Remove the screw securing the access panel, remove the
panel, then fold up the insulation.
3. Lift out the tab as shown below to unclip the terminal cover
from the thermostat. The terminal cover can now be removed
from the thermostat.
FIGURE 15.
4. Disconnect wires from thermostat.
5. Remove the thermostat from behind the thermostat bracket.
6. Place the new thermostat in the bracket making sure it fits
firmly against the tank.
7. Attach the wires to the new thermostat.
NOTE: Some of the terminals may require straight-in wiring
through an eye-opening. If wires are now looped, recut and
strip wire 3/8" to a straight length and insert.
8. Put plastic terminal cover back in place.
9. Replace the insulation to cover the thermostat.
10. Replace access panel, then turn the electric power on.

Element Cleaning/Replacement

To remove the element from your tank in order to clean or replace it:
1. Before beginning turn "OFF" the electric power supply to the
water heater.
HAZARD OF ELECTRICAL SHOCK! Before removing any
access panels or servicing the water heater, make sure the
electrical supply to the water heater is turned "OFF". Failure to
do this could result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.
2. Open a nearby hot water faucet until the water is no longer
hot.
3. Close the cold water inlet valve. Connect a hose to the drain
valve and terminate it to an adequate drain or external to the
building. Open the water heater drain valve and allow all of
the water to drain from the tank. Flush the tank with water
as needed to remove sediment.
The water passing out of the drain valve may be extremely hot.
To avoid being scalded, make sure all connections are tight and
that the water flow is directed away from any person.
4. Remove the screw securing the access panel, then
remove the panel.
16
FIGURE 16.
FIGURE 17.
FIGURE 18.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.316060153.316070153.326070153.316332

Table of Contents