Location Requirements; Electrical Requirements - Whirlpool Room Air Conditioners for Slider & Casement Windows Use And Care Manual

For slider and casement windows
Table of Contents

Advertisement

Available languages

Available languages

Parts needed
If metal casement window installation, a 3/4"(19 mm) wood
filler panel will be needed for opening greater than 151/2 ''
(39.4 cm) wide. See "Metal or Wood Casement Window
Installation."
If wood casement window installation, a 1" (2.5 cm) wood
frame will be needed. See "Metal or Wood Casement Window
Installation."
NOTE: The installation of this air conditioner
is intended to be
permanent. When installed in an apartment or rental property,
permission to make modifications
should be obtained from
owner or landlord of building prior to installation of air
conditioner.
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Proper installation is your responsibility.
Make sure you have
everything necessary for correct installation.
The location should provide:
A horizontal sliding or casement type window with a minimum
width of 151/2 '' (39.4 cm).
Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
Adequate window frame assembly and side of structure
support for weight of air conditioner. Air conditioner
weighs
approximately
82 Ibs (37.2 kg) to 100 Ibs (45 kg).
NOTE: Do not install the air conditioner in an area where the front
panel will be exposed to heat sources that will raise the panel
surface temperature above 120°F (50°C).
Window
Installation
Window opening measurements:
151/2 '' (39.4 cm) minimum opening width
22" (55.9 cm) minimum opening height
--A
-
B
_f
h
A. 15½" (39.4 cm) minimum
B. 22" (55.9cm) minimum
T'
E(ectrica)
Shock
Hazard
P(ug into a grounded
3 prong
out)et.
Do not remove
ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Fai)ure
to fo))ow
these
instructions
can reeu)t
in
death,
fire,
or e)ectrica)
shock.
The electrical ratings for your air conditioner
are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
Wiring requirements
115 volt (103.5 min. -
126.5 max.)
0-12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit
only.
Recommended
ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner
is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's
responsibility to
have a properly grounded 3 prong outlet installed by a qualified
electrical installer.
It is the customer's
responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance
with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, Massachusetts
02269