Download Print this page

Lanier Toner for 1210, 1240, 1260, 1205 491-0282 Material Safety Data Sheet

Toner for lanier 1210, 1240, 1260, 1205 fax

Advertisement

Quick Links

Identity:
Toner for 1210, 1240, 1260, 1205
Product ID:
491-0282
Synonyms
& Common
Names:
Toner for Lanier 1210, 1240, 1260, 1205
Fax
Uses:
Lanier 1210, 1240, 1260, 1205 Fax
Chemical
Formula:
Mixture
Polyester resin
Carbon black
Polyolefin wax
Organic pigment
Quaternary ammonium salt
3
*PEL as the product: 15mg/m
3
*TLV as the product: 10mg/m
HMIS Rating:
FLAMMABILITY = 1
REACTIVITY = 0
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-
toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): A manufacturer sponsored chronic inhalation study in rats using a special test toner
revealed there were no lung changes at all in the lowest exposure level (1mg/m
slight degree of fibrosis was noted in 25% of the animals at the middle exposure level (4mg/m
at the highest exposure level (16mg/m
amount of any dust retained in the lungs for a prolonged interval. The special test toner was ten times more respirable than commercially
available toner to comply with EPA testing protocol and would not function properly in Xerographic equipment.
Carbon Black is listed on the IARC Monograph and the Massachusetts Substance List. The IARC has evaluated the evidence for the
carcinogenicity of Carbon Black as inadequate to determine a carcinogenic risk for humans.
This product contains no known hazardous materials as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200.
Remove to fresh air if effects occur. Get medical
Inhalation:
attention if needed.
Skin Contact:
Wash with soap and water.
Suitable extinguishing media: CO
Extinguishing media which may not be used for safety reasons: none
This material will burn in case of fire. The decomposition products are CO, CO
Special protective equipment for fire fighters: none
LEL: n/a
UEL: n/a
MATERIAL SAFETY DATA SHEET
Section 1: Chemical Product and Company Information
Section 2: Composition / Information on Ingredients
PERCENT
> 85
1 – 5
1 – 5
1 – 5
1 – 5
3
(total dust), 5mg/m
(respirable dust)
3
(total dust), 5mg/m
(respirable dust)
Section 3: Hazards Identification
HEALTH = 1
SPECIAL = none
3
) in all animals. These findings are attributed to "Lung Overloading", a generic response to excessive
Section 4: First Aid Measures
Section 5: Fire Fighting Measures
, dry chemical, foam or water.
2
Emergency Telephone: (800) 526-4371
MSDS No.
FX-071
Issued:
02/06/2004
Supersedes:
08/12/2002
Date:
02/06/2004
Prepared by:
Lanier Worldwide, Inc. EH&S Department
(770) 496-9500
Approved by:
Larry Choskey, Manager, EH&S
European Contact:
Lanier Worldwide, Inc., Manager, Safety &
Environment, Walter Fricke,
Im Taubental D-41468 Neuss, Germany
+49-2131-387-177
CAS No.
EXPOSURE LIMITS
Confidential
1333-86-4
3.5 mg/m
Confidential
Confidential
Confidential
3
), the most relevant level to potential human exposures. A very
3
), while a slight degree of fibrosis was observed
In case of contact, immediately flush eyes with
Eye Contact:
water for 5 minutes. Get medical attention if
needed.
Ingestion:
Dilute stomach contents with several glasses
of water. Get medical attention.
Explosion limits: n/a
, and No
. Avoid inhalation of smoke.
2
x
Lanier Worldwide, Inc.
2300 Parklake Dr., N. E.
Atlanta, GA 30345-2979
SOURCE
Not listed
n/a
3
3
OSHA TWA, ACGIH TLV
, 3.5 mg/m
MAK
3
6 mg/m
Not listed
N/a
Not listed
N/a
Not listed
N/a

Advertisement

loading

Summary of Contents for Lanier Toner for 1210, 1240, 1260, 1205 491-0282

  • Page 1 02/06/2004 Synonyms Supersedes: 08/12/2002 & Common Date: 02/06/2004 Names: Toner for Lanier 1210, 1240, 1260, 1205 Prepared by: Lanier Worldwide, Inc. EH&S Department (770) 496-9500 Uses: Approved by: Larry Choskey, Manager, EH&S Lanier 1210, 1240, 1260, 1205 Fax European Contact: Lanier Worldwide, Inc., Manager, Safety &...
  • Page 2 Used Toner should be disposed of under conditions that meet all federal, state and local environmental regulations. Disposal regulations vary from locality to locality; therefore consult your local Lanier office or the EPA to determine the proper method for disposal.
  • Page 3 Notice: Judgments as to the suitability of information contained herein for purchaser’s purposes are the purchaser’s responsibility. Therefore, although reasonable care has been taken in the preparation of such information, Lanier Worldwide, Inc. extends no warranties, makes no representations, and assumes no responsibility as to the accuracy or suitability of such information for application to purchaser’s intended purposes or for consequences of its use.

This manual is also suitable for:

491-0282