TROUBLESHOOTING GUIDE

Symptom
Display will not come on.
Temperature settings will not
change (Example: cannot set
the heating higher or the
cooling lower).
Heating will not come on.
63-4356—1
Action
• Check if the circuit breaker is tripped—reset the circuit breaker.
• Check if the fuse is blown—replace the fuse.
• Check if the system switch at the equipment is in the Off position—
set to the On position.
• Check wiring between thermostat and HVAC equipment—replace
any broken wires.
• If 24 Vac is present, proceed with troubleshooting.
• Check that the temperature setpoints are:
- heating: 40 to 90°F (7 to 31°C)
- cooling: 45 to 99°F (9 to 37°C).
• Keyboard is locked. Contact the installer.
• Check if the circuit breaker is tripped—reset the circuit breaker.
• Check if the fuse is blown—replace the fuse.
• Check if the system switch at the equipment is in the Off position—
set to On position.
• If 24 Vac is present, proceed with troubleshooting.
• Wait five minutes for the system to respond.
• Set system selection to Heat.