Owner's
Manual
Ibis Owner's Guide provides specific operating instructions for your model. Use the air
conditioner
only as instructed in this guide. These instructions
are not meant to cover
every possible condition
and sKuation that may occur. Common sense and caution
must be practiced when installing, operating, and maintaining
any appliance.
Record Your Model and Serial Numbers
Record in the space provided below the model and serial numbers. The serial plate is
located on the outside of the cabinet, or behind filter at the bottom of unit, Reading
the numbers may be easier by using a flashlight
or by removing the cabinet front as
instructed under "Care and Cleaning."
Model Number:.
Serial Number:.
Purchase
Date:
P/N309000829 (10/99)
B
B
B
g
m
O
Ii
I

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore Air Conditioner

  • Page 1 Owner's Manual Ibis Owner's Guide provides specific operating instructions for your model. Use the air conditioner only as instructed in this guide. These instructions are not meant to cover every possible condition and sKuation that may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
  • Page 2: Energy Saving Ideas

    • Be sure the electrical service is adequate for the model you have chosen. • If the air conditioner is to be installedin a window, you will probably want to clean both sides of the glass first, if the window is a triple-track type with a...
  • Page 3: Normal Sounds

    The same air is then returned to the room -- cooler, drier and cleaner, Moisture removed from the room air is carried to the outside and evaporated. Your air conditioner is designed to be easy to operate and to provide plenty of cooling power. Normal Sounds...
  • Page 4: Front Installation

    Installing the Front Frame Some models require installation of the front panel of the air conditioner included in a decorative kit. To assemble, follow these steps. Before installation, remove the tilt panel from the frame. Grasping the panel from both sides, gently pull to release, then lift panel from pivot points at bottom of frame (Fig.
  • Page 5: Air Conditioner

    IMPORTANTSAFETYINSTRUCTIONS before operating this appliance. To begin operating the air conditioner, follow these steps: 1. Plug in the air conditioner. (To prevent electrical hazards, do not use an extenston cord or an adapter plug.) 2. Set the exhaust vent to the CLOSEDposition.
  • Page 6: Air Conditioner Features

    Air Conditioner Features (continued) STEP 2 -- TO CHANGE TEMPERATURE SETI"ING: YOU WILL SEE: DO THIS: TO RAISE LOWER Note: Tap or hold either up(A) or down(v) button until the desired temperature is seen on the screen, Thistemperature will be automatically maintained anywhere between 60F (15C) and 90F (32C).
  • Page 7: Step 5 -- To Operate On Fan Only

    Air Conditioner Features (continued) STEP 5 -- TO OPERATE WILL SEE: ON FAN ONLY: DO THIS: PRESS ON (if not running) PRESS FAN ONLY Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air (remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.).
  • Page 8: Step 10 -- To Turn Unit Off

    Air Conditioner Features (continued) STEP 8 -- TO INCREASE DELAYED START TIM E: WILL SEE TIME CHOSEN: DO THIS: PRESS Note: Tap or hold the UP arrow(A) to increase delayed start time by .5 hours (up to 10 hours), then in 1 hour increments up to 24 hours.
  • Page 9 Figure 1 (OFF) Fresh Air Vent Control The FreshAir Vent allows the air conditioner to recirculateinside air (OFF), draw air into the room (FRESH AIR)or exhauststale air to the outside(VENT). See Figures 1, 2 & 3 for this operation. • The "OFF" position is used when MAXIMUM cooling is desired.
  • Page 10: Care And Cleaning

    Cabinet Cleaning • Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
  • Page 11: Routine Maintenance

    Storage Routine Maintenance If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return It to the original carton. NOTE: To prevent rust or electrical connections from being damaged, store air conditioner in an upright position and a dry place.
  • Page 12 Then ... The unit is not leveled properly. The unit should Level the air conditioner, to provide a I14" downward slope to the outside slope slightly downward to the outside. (_/_ bubble on carpenter s level) to provide proper drainage. Reposition or shim the cabinet as necessary.DO NOT drill a hole in the drain pan.
  • Page 13: Warranty

    Sealed Refrigeration System For five years from the date of purchase, when this air conditioner is operated and maintained for normal room cooling according to instructions in this owner's manual, Sears will repair the sealed refrigeration system (consisting of refrigerant, connecting tubing, and compressor), free of charge, if defective in material or workmanship.

Table of Contents