Periodic Maintenance; Check Engine Oil Level; Check Battery Charge - Exmark Frontrunner 720,000 & Higher Serial Nos. Operator's Manual

Air-cooled models
Table of Contents

Advertisement

Maintenance
Maintenance Service
Interval
Monthly
Yearly

Periodic Maintenance

Check Engine Oil Level

Service Interval: Before each use or daily
1. Stop engine and wait for all moving parts to stop.
Make sure unit is on a level surface.
2. Tilt seat forward and raise hood to gain access
to access to engine area.
3. Check with engine cold.
4. Clean area around dipstick. Remove dipstick and
wipe oil off. Reinsert the dipstick and push it all
the way down into the tube. Remove the dipstick
and read the oil level.
5. If the oil level is low, wipe off the area around the
oil fill cap, remove cap and fill to the "FULL"
mark on the dipstick. Use oil as specified in
Engine Owner's Manual. Do Not overfill.
Important: Do Not operate the engine with the
oil level below the "LOW" (or "ADD") mark on
the dipstick, or over the "FULL" mark.

Check Battery Charge

Service Interval: Monthly
WARNING
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead
compounds, chemicals known to the State of
California to cause cancer and reproductive
harm. Wash hands after handling.
Maintenance Procedure
• Check the battery charge.
• Grease the fold lock pin.
• Grease the rear caster pivot.
• Grease the belt idlers.
• Grease the motion control pivots.
• Grease the transfer spring ends.
• Lubricate the caster wheel hub(s).
• Lubricate the motion control shaft.
• Change the hydraulic filter.
Allowing batteries to stand for an extended period of
time without recharging them will result in reduced
performance and service life. To preserve optimum
battery performance and life, recharge batteries in
storage when the open circuit voltage drops to 12.4
volts.
Note: To prevent damage due to freezing, battery
should be fully charged before putting away for
winter storage.
Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery in
the table and charge the battery for the recommended
time interval to bring the charge up to a full charge
of 12.6 volts or greater.
Important: Make sure the negative battery
cables are disconnected and the battery charger
used for charging the battery has an output of
16 volts and 7 amps or less to avoid damaging
the battery (see chart for recommended charger
settings).