White Rodgers 1F95CA-391 Installation & Configuration Manual page 6

90 series multi-stage/heat pump
Table of Contents

Advertisement

INSTALLER TABLE
NOTE: You must be in the User Configuration Menu to enter the Installer Table. Firmly press TIME
TIME
at same time and release to enter the Configuration Menu.
BACK
Step
Press Button(s)
1
Firmly Press
SET TIME and
SET DAY (hold
for approx. 3 seconds)
2
TIME FWD
(Heat Pump ONLY)
3
TIME FWD
4
TIME FWD
5
TIME FWD
6
TIME FWD
(Heat Pump ONLY)
7
TIME FWD
8
TIME FWD
9
TIME FWD
10
TIME FWD
(Heat Pump ONLY)
11
TIME FWD
(Heat Pump ONLY)
(Balance point temperature)
12
TIME FWD
(Heat Pump ONLY)
13
TIME FWD
(Heat Pump ONLY)
14
TIME FWD
(Heat Pump ONLY)
15
TIME FWD
16
TIME FWD
17
TIME FWD
Program RUN
* Note: COMP LOCK OFF permanently defeats compressor lockout. You must turn this selection ON if you do not have a system that already provides
compressor short-cycle protection. Please see "Lockout Bypass Option" to temporarily override compressor lockout.
Displayed (Factory Default) Press UP or DOWN to select:
MLTI STG
HEAT PUMP
(1)
ELEC HEAT FAN
(ON)
SET CYCL (05)
for MLTI_STG, (13) for
HEAT PUMP 1, (24)
for HEAT PUMP 2
SET CYCL (24)
for MLTI_STG, (13) for
HEA T PUMP 1, (24)
for HEAT PUMP 2
SET CYCL AUX
(08)
COOL FAN DELA OFF
(00)
FAN DELA ON
(01)
HEAT FAN DELA OFF
(00)
PUMP
(ON)
COMP OFF DELA
(60)
bPT (35 F )
(Balance point)
bP (05)
(Programmable Blower
Balance Point) bbP
(OFF)
COMP LOCK
(OFF)
CA
(OFF)
HEAT-OFF COOL-AUTO
or HEAT-EMER-OFF-
COOL-AUTO
(for heat pumps)
Selects type of system. Selecting HEAT PUMP
HEAT PUMP
makes additional items for heat pump systems
available.
2
1. One compressor on Y1.
2. Two compressor on Y1, Y2.
Fan cycles with call for heat if ON. Fan always
OFF
cycles with pump stages.
Selects HEAT anticipation adjustment.
1 to 40 for multi-stage
9 to 40 for heat pump
Selects COOL anticipation adjustment.
9 to 40
Selects AUXILIARY stage anticipation adjustment.
1 to 40
(Heat Pump ONLY)
Selects time delay for COOL fan OFF.
0 to 127 seconds
Selects time delay for fan ON. Applies only to
1 to 30 seconds
compressor stages for heat pump or COOL.
Selects time delay for fan ON only when
0 to 127 seconds
ELECT HEAT FAN (Step 3) is ON.
Fossil Fuel Kit Alternative option. Turns compressor
OFF
OFF if Auxiliary is ON for longer than one minute.
(Heat Pump 1 & 2)
Available if Pump (Step 10) is OFF. Selects the
(0) to (99)
delay between de-energizing fossil fuel stage and
restarting Heat Pump stage.
Available if Pump (Step 10) is OFF and OUTDOOR
5 F to 50 F
Sensor ON. Selects outdoor balance point
temperature for Heat Pump.
Available if Pump (Step 10) is OFF and OUTDOOR
(01) to (09)
Sensor OFF. The higher the number the sooner the
auxilary stage energizes. The lower the number the
longer period of time before auxiliary is energized.
Available if configured for HEAT PUMP. Adjustable
10 to 99%
from 99-10. Lowers the Blower speed if the Heat
Pump duty cycle is above the selected value in
percentage.
Selects compressor short-cycle protection.*
ON
Selects active Comfort Alert. Requires CA module
ON
and CA interface module.
Allows selection of HEAT and COOL or HEAT,
HEAT-OFF-COOL or
COOL and AUTO with SYSTEM button. (EMER
HEAT-EMER-OFF-
appears in sequence after HEAT if HEAT PUMP
COOL (for heat pumps)
is selected).
Returns to Normal Operation.
6
FWD
COMMENTS
and
See
Page
5
5
5
5
5
5
5
5
5
5
7
7
7
7
7
7
7