Description and Features
The CA8900 is a digital thermostat that can be con-
trolled wirelessly with Z-Wave controllers supporting
the Thermostat General V2 Device Class. The thermo-
stat is compatible with all standard 24 VAC heating
and cooling systems, up to two-stage heat, one-stage
cool, and two-stage heat pump. The CA8900 operates
as a simple thermostat with buttons to set target tem-
peratures for heat and cool modes. The Save Energy
button adds two more modes for target temperatures
to provide a single button set-back mode for easy op-
eration. It can easily be retrofitted to existing systems
as part of a Z-wave control strategy.
The CA8900 Wireless Thermostat provides two-way
communication as part of a Z-Wave
it receives commands from the Central Controller
Unit, it sends back confirmation that the command
was received and imple-
mented. Each module in a
Z-Wave network communi-
cates with every other mod-
ule, acting as a "repeater"
and routing your commands
to their destination by the most reliable pathway.
When Z-Wave devices (regardless of manufacturer)
are installed throughout the house, signals are au-
tomatically routed around obstacles or dead spots,
strengthening the network as more devices are added.
The Z-Wave icon shows on the lower right of the dis-
play panel, indicating that the thermostat is in contact
with the controller. If the icon is not present, commu-
nication has been lost. If this occurs, all remote HVAC
functions are shut off.
MODEL CA8900 Z-Wave
Digital Thermostat
Installation and User Instructions
network. When
®
This thermostat can be used with all 24VAC heat-
ing and cooling systems. It cannot be used with line
voltage systems.
The CA8900 is digital and your desired heat or cool
temperatures can easily be set on the large screen
with the TEMP UP (+) and TEMP DOWN (-) buttons
on the front.
A minimum 4-minute off time protects heating and
cooling systems from damage.
This thermostat uses a new technique called sequen-
tial staging for more comfort with faster reaction to
requested temperature changes.
NOTE: When using a heat pump with auxiliary
heat, if the heat pump cannot keep up and/or is
defective, remove jumper from position 2B and put
jumper on position 2A. This will make the auxiliary
heat your only source of heat. Be sure to restore it
to PUMP when the pump is again operational, as
auxiliary heat is more expensive than pump heat.
For more information, see page 3.
This guide is in two parts:
Part One: Operating Guide
for the homeowner or end user.
Part Two Installing Guide
for the installer or technician.
®

Advertisement

loading

Summary of Contents for Intermatic InTouch Z-Wave CA8900

  • Page 1 Digital Thermostat Installation and User Instructions Description and Features The CA8900 is a digital thermostat that can be con- trolled wirelessly with Z-Wave controllers supporting the Thermostat General V2 Device Class. The thermo- stat is compatible with all standard 24 VAC heating and cooling systems, up to two-stage heat, one-stage cool, and two-stage heat pump.
  • Page 2 CA8900 Z-Wave Thermostat Installation Guide ® Part One: Operating Guide Operating the CA8900 To set the thermostat to control your heating system, press the HEAT button so the word HEAT displays. Press again to turn OFF. The word HEAT will flash when the thermostat is calling for heat.
  • Page 3: Low Battery Warning

    Joining to a Z-Wave Network ® To join a Z-Wave network, set the Z-Wave controller to INCLUDE mode, then press and release the BIND button on the CA8900 thermostat. Follow instructions provided with your controller. You would also use the BIND button when excluding from a Z-Wave network.
  • Page 4 CA8900 Z-Wave Thermostat Installation Guide ® Part Two: Installing Guide WARNING–Risk of Fire or Electric Shock • To avoid fire, shock, or death, and to prevent damage to the furnace, • Do not short (jumper) across electric terminals at control on air conditioner, and thermostat, disconnect the power supply before furnace or air conditioner to test the system.
  • Page 5 Fan wires out as illustrated with CA8900 below the CA8900 to operate. Without the 24VAC power, the wall opening. CA8900 will run on its back-up batteries for just a • Wires will dress behind the CA8900 and up over the few days.
  • Page 6 CA8900. Connect the remaining wire to the A terminal. -Connect the R (or RH) wire to the RH terminal Solenoid valve on the CA8900. Connect the W wire to the A terminal on the CA8900. Connect the remaining wire to the W terminal. Go To Page 15 Motor Valve C wire to the C terminal on the CA8900.
  • Page 7 CA8900 Z-Wave Thermostat Installation Guide ® WIRES: R (or RH) wire to the RH terminal on the CA8900. This Connect the C W RH G 3 Wire connects to the Heater Power. Heat F r o m 3 Wire F u r n a c e W wire to the W terminal on the CA8900.
  • Page 8 O wire to the O terminal or B wire to the B terminal Connect WIRES: 4 Wire on the CA8900. (If you have both O and B, connect O wire to O O Y R H G Heat terminal F r o m...
  • Page 9 Thermostat Installation Guide ® 6 – Install AA Batteries While the CA8900 requires the C wire (24VAC) to operate. It also requires 2AA batteries to back-up the 24VAC power for up to a few days. Install 2 AA alkaline batteries according to the polar- ity noted in the compartment.
  • Page 10: Power Requirement

    Calibration switch and slide it to the ON Locate the OF F position. The current calibration factor (+/-) of the CA8900 will appear in the LCD display. UP or DOWN arrows until the desired cali- Push the bration factor is reached.
  • Page 11: Jumper Reference

    CA8900 Z-Wave Thermostat Installation Guide ® Jumper Reference HEAT PUMP POWER HPAUX TYPE TYPE JUMPER AUX HEAT RC-RH GAS/OIL Celsius ELECT ONLY CONCTED H-PUMP ELECTRIC RC-RH Fahrenheit REMOVED SEPARATE GAS/OIL HEAT PUMP FURN WITH AUX NO JUMPER NO JUMPER NO FAN...