Disassembly Instructions - Mitsubishi Electric MUH-GA35VB Service Manual

Split-type, heat pump air conditioners, wireless type models
Hide thumbs Also See for MUH-GA35VB:
Table of Contents

Advertisement

11

DISASSEMBLY INSTRUCTIONS

<"Terminal with locking mechanism" Detaching points>
The terminal which has the locking mechanism can be detached as shown below.
There are two types ( Refer to (1) and (2)) of the terminal with locking mechanism.
The terminal without locking mechanism can be detached by pulling it out.
Check the shape of the terminal before detaching.
(1) Slide the sleeve and check if there is a locking lever or not.
Sleeve
Locking lever
MUH-GA20VB -
E1
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws of the top panel.
(2) Remove the screw of the service panel.
(3) Remove the screws of the cabinet.
(4) Remove the screws of the front panel and motor support.
(5) Remove the service panel, and remove the screw from
the insides.
(6) Remove the top panel.
(7) Remove the cabinet.
Photo 3
Screw of the cabinet
1Slide the sleeve.
2Pull the terminal while
pushing the locking
lever.
MUH-GA25VB -
E1
Screws of the
top panel
Screw of the
Service panel
(2) The terminal with this connector has the locking
mechanism.
MUH-GA35VB -
E1
Photo 1
Screw of the front panel and motor support
Photo 2
(W) This photo shows MUH-GA20VB.
29
1Hold the sleeve, and
pull out the terminal
slowly.
Connector
PHOTOS
Screws of the cabinet
Screws of the
top panel
Screws of the
cabinet

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Muh-ga20vbMuh-ga25vb

Table of Contents