Hood Exhaust - GE JVM3660 Installation Instructions Manual

Over the range microwave oven
Hide thumbs Also See for JVM3660:
Table of Contents

Advertisement

Installation
Instructions
HOOD EXHAUST
NOTE: Read these next two pages only if you plan to vent your exhaust to the
outside. If yon plan to recirculate the air back into the room, proceed to page 6.
1
OUTSIDE
TOP EXHAUST
(EXAMPLE
ONLY)
The fbllowing chart describes an example of one possible
ductwork installation.
DUCT PIECES
RoofCap
12 Ft.StraightDuct
(6" Round)
RectangulaFto-Round
Transition Adaptor*
EQUIVALENT
LENGTH
24 Ft.
12 Ft.
x
5 Ft.
x
Equivalent l engths of duct piecesare basedon actual tests and
reflect requirements for goodventing performance with anyvent hood.
NUMBER
USED
(1)
(1)
(1)
EQUIVALENT
=
LENGTH
24 Ft.
12Ft.
5 Ft.
41 Ft.
Total Length
=
* IMPORTANT:
If a rectangular-to-round
transition
adaptor
is used, the bottom
corners of the damper
will have to be cut to fit, using the tin snips, in order to allow free movement
of the damper.
OUTSIDE
BACK EXHAUST
(EXAMPLE
ONLY)
The following chart describes an example
of one possible
ductwork
installation.
EQUIVALENT
f
,_
DUCT PIECES
LENGTH*
x
Wall Cap
40 Ft.
x
3 Ft.Straight Duct
3 Ft.
x
j
3_A" x 10" Rectangular)
(_
90° Elbow
10 Ft.
x
NUMBER
EQUIVALENT
USED
=
LENGTH
(1)
40 Ft.
(1)
3Ft.
(2)
20 Ft.
Equivalent l engthsof duct piecesare basedon actual tests and
reflect requirements for goodventingperformance with anyvent hood.
Total Length
=
63 Ft.
NOTE: For back exbaust, care sbould be taken to align exhaust witb space between studs, or wall should be prepared
at the time it is constructed
by leaving enough
space between
the wall studs to accommodate
exhaust.
4