[13] Wireless Transmitter Supervision Loss
A wireless transmitter is no longer communicating with its
receiver or its batteries are disconnected..
To view on which zones the Wireless Transmitters are
experiencing trouble, press the [
from the Trouble Display (see "How Do I Access the Trouble
Display?" at the beginning of section 2.6).
[16] Keypad Fault
If for any reason your keypad is no longer communicating
with your alarm system, the keypad will emit four consecutive
beeps at 3-second intervals. Press any button on the keypad
to terminate the "beeping" sequence. When communication
is restored, the keypad will resume its functions.

2.7 PARTITIONING

Your Spectra system is equipped with a partitioning feature
that can divide your alarm system into two distinct areas
identified as Partition 1 and Partition 2. Partitioning can be
used in installations where shared security systems are more
practical, such as a home office or warehouse building. When
partitioned, each zone, each User Code and many of your
system's features can be assigned to either Partition 1,
Partition 2, or both partitions.
If the system is not partitioned, all zones, User
Codes, and features will be recognized as
belonging to Partition 1.