LED FLASH SEQUENCE
CORRECTIVE
ACTION
Six-Two
Flash, three second
pause
Six-Three
Flash, three second pause
CONTROL STATUS
Soft Lockout*
- Recycle
Limit - Flame
Lost
-
END Switch
Fails
Soft Lockout*
- Recycle Limit - Flame Lost
Six-Four
Flash, three second
pause
Soft Lockout*
- Flame out of Sequence
Sensed
Seven
Flash, three second pause
Flammable
Vapor Sensor (FVS) Lockout
Turn the power
switch on the gas control valve to the "OFF" position
and unplug the power
cord
from the power outlet.
I.
Check all wiring connections
to insure att harness and wire connections
are seated firmly and
provide proper electrical
contact,
tf no connection
problems
are found replace
the damper.
Firmly
seat any loose connections
found.
If any connections
are found to be damaged
consult the
replacement
parts list on page 43 for the appropriate
replacement.
After any connection
problems
are fixed restart the water heater by following the lighting instructions on page 24. If the problem
persists
replace
the damper.
Turn the power
switch on the gas control valve to the 'OFF"
position
and unplug the power
cord
from the power outlet.
I.
Check
the incoming
gas line pressure
to ensure
adequate
supply
to the water heater.
If
incoming
gas supply
pressure
is adequate
proceed
to step 2.
2.
Check all wiring connections
and insure all harness and wires connections
are seated firmly
and provide proper electrical
contact.
If no connection
problems
are found proceed to step 3.
Firmly seat any loose connections
found,
tf any connections
are found to be damaged consult
the replacement
parts _ist for the appropriate
replacement.
After any connection
problems
are
fixed restart the water heater by following
the lighting instructions
on page 24.
If the proMem
persists
proceed
to step 3.
3.
Check
condition
of the base ring filter and flame
arrestor,
tf they
are clogged
follow the
instructions
for cleaning on page 32. If parts are not clogged
proceed to step 4. After cleaning
follow instructions
for lighting
on page
24. If problem
persists
proceed
to step
4.
4.
Follow the instructions
on page 31 to remove the burner assembly.
Once the burner assembly
has been removed
inspect the manifold tube and burner, see figure 36 , for any obstructions.
If any clogs
or obstructions
are present
clear them.
Inspect the electrode/flame
sense rod,
see figure 43 , for corrosion
buildup,
degradation,
or damage,
tf there
is evidence
of any
damage
to the electrode/flame
sense
rod replace
the
igniter/pilot
assembly.
Follow
the
directions
on page 32 to re-install the burner assembly
into the combustion
chamber.
Follow
the instructions
for lighting
on page
24.
If the problem
persists
contact
a qualified
service
representative.
Turn the power switch on the gas control valve to the "OFF" position and unplug the power cord from
the power outlet.
Wait 10 minutes
then follow the lighting instructions
on page 24.
If the problem
persists
replace the gas control valve.
I.
Do not touch any electrical
switch,
do not use any phone in the building
and do not try to
light any appliance.
2.
Smell around the water heater to ensure
there are no gas leaks at the gas control valve or in
the supply gas line or for any other type of flammable
vapors
in the area.
3.
Carefully
inspect
the area
surrounding
the water
heater
for any substances
such as gasoline,
paint, paint thinners,
varnish,
or cleaners that could emit flammable
vapors.
Remove
anything
that can potentially
emit flammable
vapors from the area and store it properly
in a different
location.
4.
Contact
a qualified
service
representative
for inspection
and/or
replacement
of the
FV
sensor.
Eight-One
Flash, three second pause
Flammable
Vapor Sensor (FVS) Fault Detected
Turn the power
switch on the gas control valve to the "OFF" position,
wait 10-20 seconds
then turn
the power switch on the gas control valve to the "ON" position.
If the problem
persists replace
the
gas valve.
Eight-Two
Flash, three second
pause
Temperature
Sensor Fault Detected
Turn the power
switch on the gas control valve to the "OFF" position,
wait 10-20 seconds
then turn
the power switch on the gas control valve to the "ON" position.
If the problem
persists replace
the
gas valve.
Eight-Three
Flash, three second pause
Electronic
Fault Detected
Turn the power
switch on the gas control valve to the "OFF" position,
wait 10-20 seconds
then turn
the power switch on the gas control valve to the "ON" position.
If the problem
persists replace
the
gas valve.
Eight-Four
Flash, three second pause
Gas Control Valve/Thermostat
Fault Detected
Turn the power
switch on the gas control valve to the "OFF" position,
wait 10-20 seconds
then turn
the power switch on the gas control valve to the "ON" position.
If the problem
persists replace
the
gas valve.
* Soft Lockout - 20 minute wait before returning
to normal
mode.
41