Manual Advanceregeneration Check; Wiring Schematic - Kenmore 625.384200 Use & Care Manual

With ultra flow valve
Hide thumbs Also See for 625.384200:
Table of Contents

Advertisement

MANUAL ADVANCEREGENERATION CHECK
This check verifies
proper
operation
of the valve motor,
brine tank fill, brine draw,
regeneration
flow rates, and
other controller
functions.
Always
make the initial
checks first, and perform
the manually
initiated
elec-
tronic diagnostics.
NOTE: The display
must show a steady
time (not flash-
ing).
If an error code shows, first press the
SELECT button to enter the diagnostic
display.
1. Press the REGENERATION
button
and hold in for 3
seconds.
"RECHARGE",
"Serv"
and "Fill" begin to
flash in the display
as the softener enters the fill
cycle of regeneration.
2. When valve reaches "Fill"
position,
remove the
brinewell
cover and, using a flashlight,
observe
fill
water
entering
the tank.
3. If water
does not enter the tank, look for an
obstructed
nozzle, venturi,
fill flow plug, brine tubing,
or brine valve riser pipe.
4. After observing
fill, press the REGENERATION
button
to move the softener into brining.
A slow flow of
water
to the drain will begin.
Verify
brine draw
from the brine tank by shining a flashlight
into the
brinewell
and observing
a noticeable
drop in the liq-
uid level.
.5. If the softener does not draw
brine:
nozzle and/or
venturi
dirty
nozzle and venturi
not seated
properly
on gasket
restricted
drain (check drain fitting
and hose)
• ineffective
nozzle and venturi seal
• other inner valve problem
(rotor seal, rotor & disc,
wave washer, etc.)
Position Markers
(valve in service)
Cam
Motor
o °l
Figure 45
NOTE: If water
system pressure is low, an elevated
drain hose may cause back pressure, stopping
brine draw.
6. Again
press REGENERATION
to move the softener
into backwash.
Look for a fast flow of water
from
the drain hose.
7. An obstructed
flow indicates
a plugged
top distribu-
tor, backwash
flow plug or drain hose.
8. Press REGENERATION
to move the softener
into fast
rinse.
Again
look for a fast drain flow.
Allow
the
softener
to rinse for a few minutes to flush out any
brine that may remain
in the resin tank from the
brining
cycle test.
9. To return the softener
to service, press REGENERA-
TION
once more.
WIRING
SCHEMATIC
Transformer
Back of Controller
(PWA)
AC INPUT
I
POS. / TURBINE
MOTOR
Valve
Motor
grn
Turbine
_
NO
Position
Sensor
brn
O NC
Switch
Figure 46
Questions?
Call the Kenmore
Water
Line 1-800-426-9345
or visit www.kenmorewater.com
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents