Floor Standing Type (Srf) Specifications - Mitsubishi Heavy Industries SRK50ZJ-S Technical Manual

Wall mounted /floor standing/ ceiling concealed / ceiling cassette-4way compact type inverter residential air conditioners
Hide thumbs Also See for SRK50ZJ-S:
Table of Contents

Advertisement

(2) Floor standing type (SRF)
Item
Cooling capacity (1)
Heating capacity (1)
Power supply
Power
consumption
Running
current
Inrush current
Operation
data (1)
COP
Cooling
Noise
level
Heating
Exterior dimensions (Height x Width x Depth)
Exterior appearance
( Munsell color )
Net weight
Compressor type & Q'ty
Motor (Starting method)
Refrigerant oil
Refrigerant
Refrigerant (3)
equipment
Heat exchanger
Refrigerant control
Deice control
Fan type & Q'ty
Motor
Air handling
Air flow
equipment
Fresh air intake
Air filter, Quality / Quantity
Shock & vibration absorber
Electric heater
Operation switch
Operation
Room temperature control
control
Operation Display
Safety devices
Refrigerant piping size (O.D)
Connecting method
Attached length of piping
Installation
data
Insulation for piping
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Drain hose
Power cable
Recommended breaker size
Connection wiring
Accessories (included)
Optional parts
Note (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
Model
W
W
Cooling
kW
Heating
Cooling
Heating
A
Cooling
Heating
Sound level
dB(A)
Power level
dB
Sound level
dB(A)
Power level
dB
mm
kg
kW
kg
W
Cooling
CMM
Heating
mm
m
m
A
Size x Core number
Connecting method
Indoor air temperature
DB
WB
27˚C
19˚C
20˚C
Indoor unit SRF25ZJX-S
2500 (900 (Min.)~3200 (Max.))
3400 (900 (Min.)~4700 (Max.))
1 Phase, 220~240 V, 50Hz
2.6 / 2.5 / 2.4 (220/ 230/ 240 V)
3.6 / 3.4 / 3.3 (220/ 230/ 240 V)
3.6 / 3.4 / 3.3 (220/ 230/ 240 V)
Hi : 40 Me : 32 Lo : 26
51
Hi : 40 Me : 35 Lo : 28
51
600 x 860 x 238
Fine snow
( 8.0Y 9.3/0.1 ) near equivalent
18
0.35 (DIAMOND FREEZE MA68)
R410A 1.2 (Pre-Charged up to the piping length of 15m)
Louver fins & inner grooved tubing
Capillary tubes + Electronic expansion valve
Microcomputer control
Turbo fan x 1
40
Hi : 9.0 Me : 7.6 Lo : 5.8
Hi : 10.5 Me : 8.2 Lo : 6.6
Impossible
Polypropylene net (washable) x 1
Wireless-Remote control
Microcomputer thermostat
RUN : Green, TIMER : Yellow, HI POWER : Green,
AIR OUTLET SELECTION : Green, ECONO : Green
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection (High pressure control), Cooling overload protection
Liquid line :φ6.35 (1/4") Gas line :φ9.52 (3/8")
Necessary (Both sides), independent
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Connectable (VP16)
2
1.5mm
x 4 cores (Including earth cable)
Terminal block (Screw fixing type)
Mounting kit, Clean filter (Natural enzyme filter x 1, Photocatalytic washable deodorizing filter x 1)
Interface kit (SC-BIKN-E)
Outdoor air temperature
DB
WB
35˚C
24˚C
ISO-T1, JIS C 9612
7˚C
6˚C

-
-
'10 • SR-T-091D
Adapted to RoHS directive
SRF25ZJX-S
Outdoor unit SRC25ZJX-S
0.521 (0.19~0.82)
0.723 (0.23~1.20)
4.80
4.70
47
60
47
60
595 x 780 x 290
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
38
RM-B5077MDE1 (Rotary type) x 1
0.75 (Line starting)
M fins & inner grooved tubing
Propeller fan x 1
24
29.5
27.0
Cushion rubber (for compressor)
Flare connecting
Max. 15
16
The pipe length is 7.5m.
Standards
RWB000Z053
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srf35zjx-sSrf25zjx-sSrf50zjx-sSrk20zjx-sSrk25zjx-sSrk35zjx-s ... Show all