VISCA Command Setting Values
Exposure Control (1/2)
Shutter Speed
15
14
13
12
11
10
0F
0E
0D
0C
0B
0A
09
08
07
06
05
04
03
02
01
00
Iris
11
10
0F
0E
0D
0C
0B
0A
09
08
07
06
05
04
03
02
01
00
* Number in ( ) applies to EVI-D90N/P only.
NTSC (s)
PAL (s)
1/10000
1/10000
1/6000
1/6000
1/4000
1/3500
1/3000
1/2500
1/2000
1/1750
1/1500
1/1250
1/1000
1/1000
1/725
1/600
1/500
1/425
1/350
1/300
1/250
1/215
1/180
1/150
1/125
1/120
1/100
1/100
1/90
1/75
1/60
1/50
1/30
1/25
1/15
1/12
1/8
1/6
1/4
1/3
1/2
1/2
1/1
1/1
F1.4 (F1.35)
F1.6
F2
F2.4
F2.8
F3.4
F4
F4.8
F5.6
F6.8
F8
F9.6
F11
F14
F16
F19
F22
CLOSE
Gain
0F
0E
0D
0C
0B
0A
09
08
07
06
05
04
03
02
01
00
Gain Limit
0F
0E
0D
0C
0B
0A
09
08
07
06
05
04
Command List
+28 dB
+26 dB
+24 dB
+22 dB
+20 dB
+18 dB
+16 dB
+14 dB
+12 dB
+10 dB
+8 dB
+6 dB
+4 dB
+2 dB
0 dB
–3 dB
+28 dB
+26 dB
+24 dB
+22 dB
+20 dB
+18 dB
+16 dB
+14 dB
+12 dB
+10 dB
+8 dB
+6 dB
39