Sony BRCH900 Product Manual
Sony BRCH900 Product Manual

Sony BRCH900 Product Manual

Hd color video camera
Hide thumbs Also See for BRCH900:

Advertisement

A-E99-100-11 (1)
HD Color Video Camera
Command List
Version 1.00
BRC-H900
© 2012 Sony Corporation

Advertisement

Table of Contents
loading

Summary of Contents for Sony BRCH900

  • Page 1 A-E99-100-11 (1) HD Color Video Camera Command List Version 1.00 BRC-H900 © 2012 Sony Corporation...
  • Page 2: Table Of Contents

    Table of Contents VISCA RS-232C/RS-422 Commands ....3 Overview of VISCA ........... 3 VISCA Communication Specifications ..... 4 VISCA Device Setting Command ..... 6 VISCA Command/ACK Protocol ...... 7 VISCA Camera-Issued Messages ...... 8 BRC-H900 Commands ......... 9 BRC-H900 Command List (1/5) ......9 BRC-H900 Command List (2/5) ......
  • Page 3: Visca Rs-232C/Rs-422 Commands

    0 is used, set the camera address selectors on the connected BRC-H900 cameras to different numbers............................................. 1) VISCA is a protocol developed by Sony for controlling a consumer’s camcorder. “VISCA” is a trademark of Sony Corporation.
  • Page 4: Visca Communication Specifications

    BRC-H900 assigned address 2 is 82H. In the command VISCA Communication list, as the header is 8X, input the address of the BRC- Specifications H900 to X. The header of the reply packet from the BRC-H900 assigned address 1 is 90H. The packet from the BRC-H900 assigned address 2 is A0H.
  • Page 5 Command and inquiry Socket number • Command When command messages are sent to the BRC-H900, it Sends operational commands to the BRC-H900. is normal to send the next command message after receiving the completion message or error message. • Inquiry However, to deal with advanced uses, the BRC-H900 Used for inquiring about the current state of the BRC- has two buffers (memories) for commands, so that up to...
  • Page 6: Visca Device Setting Command

    Returns information on the VISCA interface. Inquiry Inquiry Packet Reply Packet Description CAM_VersionInq 8X 09 00 02 FF Y0 50 GG GG HH HH JJ JJ KK FF GGGG = Vender ID (0001: Sony) HHHH = Model ID 0501: BRC-H700 0502: BRU-H700 0505: BRC-Z700...
  • Page 7: Visca Command/Ack Protocol

    VISCA Command/ACK Protocol Command Command Message Reply Message Comments General Command 81 01 04 38 02 FF 90 41 FF (ACK)+90 51 FF Returns ACK when a command has been accepted, or (Example) (Completion) Completion when a command has been executed. 90 42 FF 90 52 FF 81 01 04 38 FF...
  • Page 8: Visca Camera-Issued Messages

    VISCA Camera-Issued Messages ACK/Completion Messages Command Command Message Comments z0 4y FF Returned when the command is accepted. (y: Socket No.) Completion z0 5y FF Returned when the command has been executed. (y: Socket No.) z = Device address + 8 Error Messages Command Command Message...
  • Page 9: Brc-H900 Commands

    BRC-H900 Commands BRC-H900 Command List (1/5) Command Set Command Command Packet Comments EXPOSURE MODE FULL AUTO 8x 01 04 39 00 FF MANUAL 8x 01 04 39 03 FF SHUTTER Pri 8x 01 04 39 0A FF IRIS Pri 8x 01 04 39 0B FF BACK LIGHT 8x 01 04 33 02 FF Available only when MODE is set to FULL AUTO.
  • Page 10: Brc-H900 Command List (2/5)

    BRC-H900 Command List (2/5) Command Set Command Command Packet Comments COLOR WHITE 8x 01 04 35 0p FF p 0: AUTO 1: INDOOR 2: OUTDOOR 3: ONE BALANCE PUSH 5: MANUAL One Push WB 8x 01 04 10 05 FF Trigger R.GAIN Reset...
  • Page 11: Brc-H900 Command List (3/5)

    BRC-H900 Command List (3/5) Command Set Command Command Packet Comments COLOR COLOR DETAIL - 8x 01 7E 01 68 0p FF p 2: ON 3: OFF DETAIL LEVEL Direct 8x 01 7E 01 69 0p 0q FF pq: 00 (-99) - 63 (00) - C6 (+99) AREA 8x 01 7E 01 6A 0p FF p 2: ON 3: OFF...
  • Page 12: Brc-H900 Command List (4/5)

    BRC-H900 Command List (4/5) Command Set Command Command Packet Comments VIDEO OUT D-SUB 15 8x 01 7E 01 03 00 0p FF p: 0 RGB 1: YPbPr FORMAT 8x 01 7E 01 07 00 0p FF p: 0 RGB SYNC OFF 2: RGB SYNCON SYNC(RGB) SYNC TYPE 8x 01 7E 01 1A 00 0p FF...
  • Page 13: Brc-H900 Command List (5/5)

    BRC-H900 Command List (5/5) Command Set Command Command Packet Comments TITLE Display Title Set1 8x 01 7E 01 10 uu vv 0w 00 uu: Character start position display, H position 00-1A (Standard) 00 00 00 00 00 00 FF vv: Character start position display, V position 00-0D w: Blinking character display 1 ON, 0 OFF Title Set2...
  • Page 14: Brc-H900 Inquiry Command List (1/3)

    BRC-H900 Inquiry Command List (1/3) Inquiry Command Command Packet Inquiry Packet Comments EXPOSURE MODE FULL AUTO 8x 09 04 39 FF y0 50 0p FF p: 0 FULL AUTO 3 MANUAL A IRIS Pri SHUTTER Pri B IRIS Pri SHUTTER Pri MANUAL Inquiry BACK LIGHT ON/...
  • Page 15: Brc-H900 Inquiry Command List (2/3)

    BRC-H900 Inquiry Command List (2/3) Inquiry Command Command Packet Inquiry Packet Comments DETAIL DETAIL 8x 09 7E 01 60 FF y0 50 0p FF LEVEL 8x 09 04 42 FF y0 50 00 00 0p 0q FF pq: 00 (-99) - 63 (00) - C6 (+99) FREQUENCY - 8x 09 7E 01 61 FF y0 50 00 00 0p 0q FF pq: 00 (-99) - 63 (00) - C6 (+99)
  • Page 16: Brc-H900 Inquiry Command List (3/3)

    BRC-H900 Inquiry Command List (3/3) Inquiry Command Command Packet Inquiry Packet Comments VIDEO D-SUB 15 8x 09 7E 01 03 FF y0 50 0p FF p: 0 RGB 1: YPbPr FORMAT 8x 09 7E 01 07 FF y0 50 0p FF p: 0 RGB SYNC OFF 2: RGB SYNC(RGB) SYNCON...
  • Page 17: Brc-H900 Block Inquiry Command List

    BRC-H900 Block Inquiry Command List Lens control system inquiry commands…..Command Packet 8x 09 7E 7E 00 FF Byte Comments Byte Comments Byte Comments Destination Address Source Address Focus Mode (1: Auto 0: Manual) Focus Position (HH) Zoom Position (HH) Camera Memory Recall (1: Executing 0: Stopped) Focus Command...
  • Page 18 Camera control system inquiry commands (1/2)…..Command Packet 8x 09 7E 7E 01 FF Byte Comments Byte Comments Byte Comments Destination Address COLOR SPEED (1 - 5) EXPOSURE MODE WHITE BALANCE Manual Gain Position Source Address MODE (0: Auto 1: Indoor 2: Outdoor 3: Onepush 5: Manual) IMG FLIP MODE...
  • Page 19 Camera control system inquiry commands (2/2)…..Command Packet 8x 09 7E 7E 02 FF Byte Comments Byte Comments Byte Comments Destination Address STEADY SHOT (1: On 0: Off) AGC MODE (1: ON 0: OFF) Source Address AGC LIMIT FLICKER CANCEL (0: 3dB 1: 6dB 2: 9dB (1: On 0: Off) 3: 12dB 4: 18dB) FRECKER CANCEL...
  • Page 20 Other enlargement inquiry commands (1/5) ..Command Packet 8x 09 7E 7E 03 FF Byte Comments Byte Comments Byte Comments Destination Address G-B (H) Source Address G-B (L) B-G (H) B-R (H) B-G (L) R-B (H) B-R (L) R-B (L) Camera block FAN rotating status (1: Rotating 0: Stop)
  • Page 21 Other enlargement inquiry commands (2/5) ..Command Packet 8x 09 7E 7E 04 FF Byte Comments Byte Comments Byte Comments Destination Address Gain Current Position DETAIL LEVEL (H) Source Address DETAIL FREQUENCY DETAIL LEVEL (L) COLOR DETAIL AREA INDICATION (1: ON 0: OFF) DETAIL FREQUENCY Current R GAIN (H)
  • Page 22 Other enlargement inquiry commands (3/5) ..Command Packet 8x 09 7E 7E 05 FF Byte Comments Byte Comments Byte Comments Destination Address DETAIL WHITE COLOR DETAIL Source Address LIMITTER (H) SATURATION (H) DETAIL WHITE COLOR DETAIL LIMITTER (L) SATURATION (L) V DETAIL CREATION 0 - 3 DETAIL BLACK...
  • Page 23 Other enlargement inquiry commands (4/5) ..Command Packet 8x 09 7E 7E 06 FF Byte Comments Byte Comments Byte Comments Destination Address AUTO KNEE (1: ON 0: OFF) KNEE MODE (1: ON 0: OFF) GAMMA LEVEL (H) Source Address KNEE POINT (H) GAMMA LEVEL (L) KNEE POINT (L) COLOR DETAIL...
  • Page 24 Other enlargement inquiry commands (5/5) ..Command Packet 8x 09 7E 7E 07 FF Byte Comments Byte Comments Byte Comments Destination Address Source Address BLACK LEVEL (H) BLACK LEVEL (L) BLACK GAMM LEVEL BLACK GAMM LEVEL...
  • Page 25: Visca Command Setting Values

    VISCA Command Setting Values IRIS GAIN Parameter Parameter F No. Gain (dB) F1.9 (OPEN) F2.2 F2.4 F2.6 F2.8 F3.1 F3.4 F3.7 F4.4 F4.8 F5.2 F5.6 F6.2 F6.8 F7.3 F8.7 F9.6 CLOSE SHUTTER Parameter Shutter Speed (sec) 1/8000 1/4000 1/2000 1/1000 1/500 1/250 1/125...
  • Page 26 Pan/Tilt Position (for reference) Focus Ratio and Focus Distance (for reference) Focus Ratio Focus Distance Left Right ∞ Angle (degrees) 1000 Yp Yq Yr Ys Yt Yp Yq Yr Ys Yt 2000 14.6m 00000 00000 3000 6.3m 00938 FF6C8 4000 3.9m 01270 FED90...
  • Page 27: Pan/Tilt Status Code List

    Pan/Tilt Status Code List – – – – – – – – – – – – – Panning reaches the end of the left. – – – – – – – – – – – – – Panning reaches the end of the right. –...
  • Page 28: Memory Function (Inquiry Commands)

    Memory Function (Inquiry Commands) Preset No. pp: Memory number Comments last operated last operated – While no Recall commands are used after the power has been tuned on ≠ 00 (or =00 for Reset, Set and Recall commands)
  • Page 29: Revision History

    Revision History Version Item Description 1.00 New edition...

Table of Contents