HE360A,B POWERED FLOW-THROUGH HUMIDIFIER
WIRING
CAUTION
Hazardous Voltage.
Can cause personal injury or equipment damage.
Disconnect power supply before installing or servicing equipment.
IMPORTANT
All wiring must comply with applicable local code, ordinances and regula-
tions.
Wire the humidifier solenoid valve, sail switch, humidistat and transformer.See Fig. 12.
1. Run the two-strand thermostat wire from the humidifier to the humidistat, and
from the humidistat to the sail switch.
2. Cut lengths of thermostat wire to reach between components, leaving adequate
wire at both ends for connections.
NOTE: Humidistat and sail switch can be wired in any order.
3. At the humidifier, connect the black and white conductors to the two yellow
humidifier wires. (The red wires from the humidifier are not used.)
4. At the humidistat, connect both black conductors to the two humidistat terminals.
Use a wire nut to connect together the two white conductors.
5. At the sail switch, connect the black and white conductors to the Com and NO
sail switch terminals (NC terminal is not used).
69-1176—04
HUMIDIFIER
BLACK
SOLENOID
WHITE
VALVE
Fig. 12. Wiring the controls.
16
HUMIDISTAT
SAIL
SWITCH
WHITE
M20205