Smart Self Test Log Data Format - Fujitsu MPE3XXXAE Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Bit
5 to F
The host computer can issue the SMART Execute Off-line Immediate sub-command (FR
Register = D4h) and cause the device to execute a self test. When the self test is completed,
the device saves the SMART self test log to the disk medium.
The host computer can issue the SMART Read Log Sector sub-command (FR Register = D5h,
SN Register = 06h) and can read the SMART self test log.
Byte
00, 01
02
03
04, 05
06
07 to 0A
0B to 19
1A to 1F9
1FA, 1FB
1FC
1FD, 1FE
1FF
Self test log 1 to 21
When executes self test, the self test index value is incremented and the self test execution
result is recorded in the self log test area specified by this value. When the self test index
exceeds 21, it returns to 01.
5 - 58
0
Unclear status
1
Sleep status
2
Standby status
3
Active status or idle status (BSY bit = 0)
4
Off-line data collection being executed
Reserved
Table 5.12 SMART self test log data format
Self test log data format version number
Self test log 1
Self test log 2 to
21
Vendor unique
Self test index
Reserved
Check sum
C141-E093-01EN
Meaning
Item
Self test mode (SN Register Value)
Self test execution status
Total power on time until the self test is
completed. [hours]
Self test error No.
Error LBA
Vendor unique
(Each log data format is the same as that in
byte 02 to 19.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpe3043aeMpe3084aeMpe3173ae

Table of Contents