If an attribute value is below the insurance failure threshold value, the device is about to fail or
the device is nearing the end of its life . In this case, the host recommends that the user
quickly backs up the data.
At command issuance (I-O registers setting contents)
1F7
(CM)
1
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(FR)
H
At command completion (I-O registers setting contents)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
The attribute value information is 512-byte data; the format of this data is shown below. The
host can access this data using the SMART Read Attribute Values subcommand (FR register =
D0h). The insurance failure threshold value data is 512-byte data; the format of this data is
shown below. The host can access this data using the SMART Read Attribute Thresholds
subcommand (FR register = D1h).
0
1
1
0
DV
Key (C2h)
Key (4Fh)
xx
xx
Subcommand
Status information
DV
Key-failure prediction status (C2h-2Ch)
Key-failure prediction status (4Fh-F4h)
xx
xx
Error information
C141-E093-01EN
0
0
0
xx
xx
5 - 51