(3)
Current Requirements and Power Dissipation
Table 1.3 lists the current and power dissipation.
Mode of Operation
Model
MPD3043
AT
Spin up
1500
1900 peak
Idle (Ready) (*3)
130
R/W (On Track) (*4)
168
Seek (Random) (*5)
325
Standby
6.5
Sleep
6.5
*1 Current is typical rms except for spin up.
*2 Power requirements reflect nominal values for +12V and +5V power.
*3 Idle mode is in effect when the drive is not reading, writing, seeking, or executing any commands. A portion of the R/W circuitry is powered
down, the spindle motor is up to speed and the Drive ready condition exists.
*4 R/W mode is defined as 50% read operations and 50% write operations on a single physical track.
*5 Seek mode is defined as continuous random seek operations with minimum controller delay.
1 - 6
Table 1.3

Current and power dissipation

Typical RMS current (*1) [mA]
+12 V
MPD3064/
MPD3108/
MPD3173
MPD3084
MPD3130
AT
AT
AT
1500
1600
1600
1900 peak
1900 peak
1900 peak
177
205
230
213
240
267
350
377
404
6.5
6.5
6.5
6.5
6.5
6.5
C141-E069-02EN
Typical Power (*2) [watts]
+5 V
All Models
MPD3043
MPD3064/
AT
MPD3084
AT
560
20.8
20.8
600 peak
280
3.0
3.5
560
4.8
5.4
544
6.6
6.9
157
0.9
0.9
152
0.8
0.8
MPD3108/
MPD3173
MPD3130
AT
AT
22.0
22.0
3.8
4.2
5.7
6.0
7.2
7.6
0.9
0.9
0.8
0.8