Format Of Device Attribute Value Data - Fujitsu MPD3XXXAT Product Manual

Mpd3xxxat series
Hide thumbs Also See for MPD3XXXAT:
Table of Contents

Advertisement

The attribute value information is 512-byte data; the format of this data is shown below. The
host can access this data using the SMART Read Attribute Values subcommand (FR register =
D0h). The insurance failure threshold value data is 512-byte data; the format of this data is
shown below. The host can access this data using the SMART Read Attribute Thresholds
subcommand (FR register = D1h).
Table 5.9 Format of device attribute value data
Byte
00
01
02
Attribute 1
03
04
05
06
07
to
0C
0D
0E
Attribute 2 to
to
attribute 30
169
16A
Reserved
to
16F
170
Failure prediction capability flag
171
172
Reserved
to
181
182
Vendor specific
to
1FE
1FF
Check sum
Item
Data format version number
Attribute ID
Status flag
Current attribute value
Attribute value for worst case so far
Raw attribute value
Reserved
(The format of each attribute value is the same as
that of bytes 02 to 0D.)
C141-E069-02EN
5 - 51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpd3173atMpd3043atMpd3064atMpd3084atMpd3108atMpd3130at

Table of Contents