Led Error Codes - Dell Mobile Venue Owner's Manual

Dell latitude 10 - st2 owner's manual
Hide thumbs Also See for Mobile Venue:
Table of Contents

Advertisement

Code
Cause and Troubleshooting Steps
1
BIOS ROM checksum in progress or failure
System board failure, covers BIOS corruption or ROM error
2
No RAM detected
No memory detected
3
Chipset Error (North and South Bridge Chipset, DMA/IMR/ Timer Error) , Time-Of-Day Clock test
failure , Gate A20 failure , Super I/O chip failure , Keyboard controller test failure
System board failure
4
RAM Read/Write failure
Memory failure
5
Real-time clock power fail
CMOS battery failure
6
Video BIOS test failure
Video card failure
7
CPU - cache test failure
Processor failure
8
Display
Display failure

LED Error Codes

Diagnostic LED codes are communicated via the Power Button LED. The Power Button LED blinks the corresponding
LED codes for the corresponding fault condition. Example: For No Memory detected (LED code 2) , The Power Button
LED blinks two times followed by a pause, blinks two times, pause, etc. This pattern continues until the system is
powered off.
Code
Cause and Troubleshooting Steps
1
System board: BIOS ROM failure
System board failure, covers BIOS corruption or ROM error
2
Memory
No memory/RAM detected
3
Chipset Error (North and South Bridge Chipset, DMA/IMR/ Timer Error) , Time-Of-Day Clock test
failure , Gate A20 failure , Super I/O chip failure , Keyboard controller test failure
System board failure
4
RAM Read/Write failure
Memory failure
5
Real-time clock power fail
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents