General Information

Electrical Requirement
CAUTION
Normal grounded household current,
120 volts, 60 Hz, 15 amps, single phase.
Electrical installation should comply with
national and local codes.
Air Supply and Ventilation
Means must be provided for any heavy-duty
cooking appliance to exhaust combustion
waste product to the outside of the building.
It is recommended that the cooktop be set
under a powered, vented exhaust hood, or
non-vented recirculating hood. Nothing
should obstruct the flow of combustion and
ventilation air.
WARNING
Gas Manifold Pressure
Natural gas – 5.0" W.C.P.
LP/Propane – 10.0" W.C.P.
Flexible Connections
If the unit is to be installed with flexible
• All openings in the wall behind the
couplings and/or quick disconnect fittings,
appliance and in the floor under the
the installer must use a flexible connector of
appliance shall be sealed.
at least 1/2" I.D. (1.3 cm) NPT with suitable
strain reliefs and comply with ANSI Z21.41
• Keep appliance area clear and free from
and Z21.69 standards.
combustible materials, gasoline, and other
flammable vapors.
• DO NOT obstruct the flow of combustion
and ventilation air.
• Disconnect the electrical supply to the
appliance before servicing.
When removing cooktop for cleaning and/or
service:
• Shut off gas at main supply
• Disconnect AC power supply
• Disconnect gas line to the inlet pipe.
• Lift appliance out of cabinet cutout.
14

Installation

1
Remove the grates and burner caps.
Gas & Electrical Connection
1
Note: Refer to
"Electrical & Gas
Requirements"
section for
proper
installation
information.
15
2
Turn the cooktop over and place into countertop
opening.