Wiring Diagram 170 Fav (No Thermostat); Wiring Diagrams - Mr. Heater MH170FAVT Operating Instructions And Owner's Manual

Mr. heater forced-air propane construction heater
Table of Contents

Advertisement

Model #170FAV (WITHOUT THERMOSTAT) wIRINg DIAgRAM

wIRINg DIAgRAMS

B
Y
W
G
LINE CORD
B
COLOR CODE
LEGEND
B BLACK
R RED
FEMALE CONN.
Y YEL
RING CONN.
W WHITE
O ORG
G GREEN
wIRINg CHART (wire: Type Awg 150
Color
Length
Yellow
18" (406mm)
Yellow
18" (406mm)
Operating Instructions and Owner's Manual
CONNECTION DIAGRAM
HIGH LIMIT
SWITCH X 2
MOTOR
THERMOCOUPLE
Y
TO WIRE
IGNITION CONTROL
B
TEMP
MOTOR
VAC INPUT
SPARK PLUG
O**
HV TRANS
GND
G
SCREW
NOTE:
If any original wiring as supplied with the heater, must be replaced, It must be replaced with
Type AWG 105° C wire or its equivalent, except as indicated (Type SF 2.200, **SGI-250° C)
C or equivalent (Type SF2‑200, **SgI‑250
o
From
High Limit
High Limit
SCHEMATIC DIAGRAM
B
VAC INPUT
MOTOR
TEMP
HV TRANS
IGNITION
CONTROL
TO WIRE
TO WIRE
GND
SCREW
115V
60HZ
TEMP
MOTOR
VAC INPUT
To
Ignition Control Temp. Terminal
Ignition Control Temp Terminal
8
Enerco Group, Inc. | Force-Air Propane Construction Heater
SPARK
HIGH LIMIT
PLUG
SWITCH X2
TO JUNCTION
C))
o
MOTOR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents