4. Test Procedure

4-1 List of Equipment
- DC Power Supply
- Test Jig
- Test Cable
- CDMA Mobile Station Test Set
- Spectrum Analyzer(include CDMA Test Mode) HP8596E
4-2 Configuration of Test
CAUTION : The test jig and data cable has a voltage drop of 0.33V at FM Max power output,
you'd better set the DC power supply to 3.93V for normal test condition.
(Nominal voltage of battery is 3.6V at cellular phone)
4-1
HP8924C, HP83236A, CMD-80, etc
Directional
Coupler
Test Jig
DC Power Supply
(+3.93V)
Spectrum Analyzer
RF In
HP8924C
RF
In/Out
To A-Out
To A-In
Audio
Audio
Out
In