Flow Chart of Troubleshooting
9-1-5. Microphone Part
Microphone does not work
Check the
assembled status of
microphone.
YES
Check the reference
voltage on mic path
R435=2.9V
YES
Is microphone ok?
YES
END
This Document can not be used without Samsung's authorization
NO
NO
NO
SAMSUNG Proprietary-Contents may change without notice
Reassemblage microphone
resolder or change
( R 4 3 5 ,R 4 3 8 , R 4 3 9 , R 4 4 0 ,
R 4 4 3 , C 4 4 0 , C 44 3 , U 4 0 7 )
Check U300