AEG ARCTIS G 78850i Operating And Installation Instructions page 23

Built-in freezer
Table of Contents

Advertisement

Symptoms
Yellow light does not light
up, when the fast freeze
function is activated,
appliance is on.
The compressor runs con-
tinuously
Heavy build up of frost,
possibly also on the door
seal.
The freezer temperature is
not sufficient, red light
illuminates, temperature
alarm signal sounds.
The compressor does not
start immediately after
changing the temperature
setting.
Important: regularly check on the red temperature pilot light and
thermometer to establish that the storage temperature is being main-
tained.
Possible Cause
Yellow light faulty.
Temperature is set too
cold.
Door seal is not airtight
(possibly after reversing
the door).
Temperature is not proper-
ly adjusted.
Door was open for an
extended period.
A large quantity of warm
food placed in the appli-
ance within the last 24
hours.
The appliance is near a
heat source.
This is normal, no error has
occurred.
Remedy
Please inform your local
Service Force Centre.
Turn the thermostat con-
trol knob to a warmer set-
ting temporarily.
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
Please look in the "Initial
Start Up" section.
Do not leave the door
open any longer than nec-
essary. Press the fast freeze
switch.
Press the fast freeze
switch.
Please look in the
"Installation Location"
section.
The compressor starts after
a period of time.
23