Download Print this page

SkyLink UR-100 User Instructions

Garage door/ gate opener universal receiver

Advertisement

Quick Links

PROGRAMMING THE RECEIVER
The Universal receiver works with Skylink remote transmitters
model #66, #66C, #36, #36C, #68, #68C, #68B, #68G, #68R,
#88, #88C, #88P. Use a paper clip to set the receiver DIP
switches to match your Skylink transmitter. Each switch of the
receiver has 2 positions ("ON" or "OFF").
DIP
SWITCHES
WARNING: Unplug the
receiver before chang-
ing code setting.
PROGRAMMING THE SKYLINK MODEL #66, 66C
1. Locate frequency switch
2. To program the model
on the top of the trans-
#66, #66C, open the
mitter and set to position
case with a coin. (See
A. (See diagram A)
diagram B)
Diagram B
Diagram A
2. To program the model
1. Locate frequency switch
on the top of the trans-
#38, #38C, open the
mitter and set to position
case with a coin. (See
A. (See diagram G)
diagram H)
Diagram H
Diagram G
Refer to the chart below. If any of the DIP switches in the Universal Receiver
are set to "ON" position, set the switches in the Skylink transmitter to the "+"
position. If DIP switches on the Universal Receiver are set to "OFF" position,
set the switches in the Skylink transmitter to the "0" or central or blank position.
DIP switch setting to match with Skylink Universal Receiver and Skylink Transmitter
UNIVERSAL RECEIVER #UR100
DIP SWITCH POSITION SETTING
1
ON / OFF
2
ON / OFF
3
ON / OFF
4
ON / OFF
5
ON / OFF
6
ON / OFF
7
ON / OFF
8
ON / OFF
9
ON / OFF
3. Use a pen or paper clip
the transmitter at "0" or
to set the corresponding
the center position. (See
DIP switches numbered
diagram C)
1 through 9 so that the
DIP Switch Location
switches on the trans-
mitter match those on
the receiver. Each switch
of the transmitter has 3
positions (" + ", " 0 ",
" - "). To operate with
Skylink #UR-100, only
set the switches to " + "
Diagram C
or " 0 ". Do not use " - "
4. Test the transmitter with
position. Leave the re-
the Universal receiver.
maining DIP switches in
PROGRAMMING THE SKYLINK MODEL #38, #38C
3. The transmitter contains 8
brand jumpers (see dia-
gram I) and 12 code con-
nectors. (See diagram J).
Code connector Location
4. The brand jumper has 8 rows
of posts, each row has 2 posts.
(see diagram I). The connec-
tor, (see diagram K), must be
placed to the position ' 7 '.
5. The code connector (see dia-
gram J) has 12 rows of posts,
1 2 3 4 5 6 7 8
each rows has 3 posts. Each
Brand Jumper
1. Disconnect the power from
your existing garage door
opener to avoid triggering
the door accidentally dur-
ing installation.
SKYLINK TRANSMITTER
2. Open your existing wall
DIP SWITCH POSITION SETTING
mounted garage door
1
+ OR 0
opener button.
2
+ OR 0
3. Connect the wires to the
3
+ OR 0
4
+ OR 0
terminals and tighten as
5
+ OR 0
shown. If your opener has
6
+ OR 0
more than two terminals,
7
+ OR 0
attach the wire to the same
8
+ OR 0
two terminals that the wire
9
+ OR 0
PROGRAMMING THE SKYLINK MODEL #36, 36C
2. To program the model
1. Locate frequency switch
#36, #36C, open the
on the top of the trans-
mitter to position A.
case with a coin. (See
diagram E)
(See diagram D)
Diagram D
row contains one connec-
tor (see diagram K) for a
total of 12 connectors.
Diagram I
Diagram J
Diagram K
INSTALLATION
from the garage door
opener is connected to.
DO NOT REMOVE ANY
WIRES.
Replace button casing.
4. Plug in the wires to the
receiver as shown. Then,
plug in the receiver to an
electrical outlet.
5. Re-connect the power to
your garage door operator.
6. Press the wall button to
test and check wiring for
3. Use a pen or paper clip
to set the corresponding
DIP switches numbered
1 through 9 so that the
switches on the trans-
mitter match those on
the receiver. Each switch
of the transmitter has 3
positions (" + ", " 0 ",
" - "). To operate with
Skylink #UR-100, only
set the switches to " + "
Diagram E
or " 0 ". Do not use " - "
position. Leave the re-
maining DIP switches in
If the connector is placed on the top and middle posts, that
row is set on " + " or "ON". If the connector is removed com-
pletely, (not placed on any posts), it is set to " 0 " or the neu-
tral position. (see diagram L for examples of how to set a row
to the three different positions).
To operate with Skylink #UR100,
only set to " + "or " 0 " position.
Do not place the connector to
the middle & bottom posts " - "
position.
When removing a connector to
set a row to the neutral position,
save the connector in case you
change the code at a later date.
proper operation.
Existing wall
mounted button
ANTENNA
RECEIVER
the transmitter at "0" or
the center position. (See
diagram F)
DIP Switch Location
Diagram F
4. Test the transmitter with
the Universal receiver.
+
'
' OR 'ON'
'0' = BLANK
Diagram L

Advertisement

loading

Summary of Contents for SkyLink UR-100

  • Page 1 #66, #66C, #36, #36C, #68, #68C, #68B, #68G, #68R, are set to “ON” position, set the switches in the Skylink transmitter to the “+” your existing garage door Existing wall position. If DIP switches on the Universal Receiver are set to “OFF” position, opener to avoid triggering #88, #88C, #88P.
  • Page 2 (see diagram mitter and set to position posts. (see diagram P) #68R, open the case those on the receiver. To operate with Skylink #UR100, only M) When repositioning connec- mitter match those on the A. (See diagram N) with a coin.