10 Technical data
Absorber type
Dimensions (L x W x H)
Weight
Volume
Max. pressure
Stagnation temperature
Gross area
Aperture surface area
Absorber surface area
Absorber
Coating
Glass covering
Glass type
Transmission
Back wall insulation
Edge insulation
Efficiency Ko
Heat capacity
Heat loss factor (k
)
1
Heat loss factor (k
)
2
Table 10.1 Technical data
Installation manual auroTHERM 0020057143_02
Units
VFK 145 H/V
mm
kg
l
bar
°C
m
2
m
2
m
2
mm
mm
Solar safety glass (prismatic structure)
W = 91
%
mm
W/m
2
K
3
kg/m
80.1 (H)
%
79.1 (V)
2
Ws/m
K
3.32 (H)
W/m
2
K
2.41 (V)
0.023 (H)
W/m
2
K
2
0.049 (V)
Serpentine horiz./vert.
2033 x 1233 x 80 (V)
1233 x 2033 x 80 (H)
38
2.16 (H)
1.85 (V)
10
171
2.51
2.35
2.33
Aluminium (vacuum coated) 0.5 x 1178 x 1978
High selective (blue)
D = 95 %
H = 5 %
3.2 (thickness) x 1233 x 2033
40
O = 0.035
U = 55
none
9700 (H)
8200 (V)
Technical data 10
VFK 150 H/V
172
Solar safety glass
(anti-reflex coating)
W = 96
84.2 (H)
83.3 (V)
3.82 (H)
2.33 (V)
0.018 (H)
0.049 (V)
GB
27