Operation; Overview Of The Operating Controls - Vaillant ecoCRAFT VKK GB SERIES Operating Manual

Gas condensing boiler
Table of Contents

Advertisement

4 Operation

4
Operation
4.1

Overview of the operating controls

9
8
7
6
5
Fig. 4.1 ecoCRAFT operating controls
To open the front panel, grip the recess and fold the
panel out. You can now see the controls with the follow-
ing functions (cp. Fig. 4.1):
1
Display indicating the current heating flow tem-
perature, the filling pressure of the heating sys-
tem, the operating mode and other additional in-
formation
2
Button "i" for calling up information
3
Controller (accessory)
4
Button for switching the unit on and off.
5
"+" button for navigating forwards through the
display view (used by expert technician to speci-
fy settings and for troubleshooting) or for dis-
playing the cylinder temperature (with cylinder
sensor)
6
"–" button for navigating backwards through the
display view (used by expert technician to speci-
fy settings and for troubleshooting) and for dis-
playing the filling pressure of the heating system
7
"Reset" button for resetting the system in the
case of specific faults
8
Rotary knob for setting the heating flow temper-
ature. When using with the VRC 430, 630 and
VRS 620, set to the clockwise end stop so that
the maximum flow temperature for the controller
will not be limited.
8
9
Rotary knob for setting the storage tank temper-
ature (on units with the VIH domestic hot water
cylinder connected ). When using the VRC 430
for controlling the cylinder temperature, set the
knob to the clockwise end stop so that the work-
1
ing range of the hot water regulator in the
2
VRC 430 will not be restricted.
Digital Information and Analysis System (DIA)
3
4
Fig. 4.2 ecoCRAFT display
ecoCRAFT units are equipped with a Digital Information
and Analysis System. This system provides information
on the operating status of your appliance and helps you
deal with problems.
During normal operation, the display (1) shows the cur-
rent heating flow temperature (in this example 49 °C). If
a fault develops, an error code appears instead of the
temperature. In addition, your ecoCRAFT has a plain
text display which is used for displaying supplementary
information.
11
The current heating flow temperature, the heating
system filling pressure or a status or error code
12
Plain text display
You can also see the following information from
the symbols displayed:
Flue problem
Flue problem
Only in combination with the vrnetDIALOG:
As long as this symbol appears in the display, the
heating flow temperature and hot water outlet
temperature are specified by vrnetDIALOG (ac-
cessory), which means the unit operates at tem-
peratures other than those set using the rotary
knobs (8) and (9).
11
12
Operating manual ecoCRAFT 0020058717_03