Tested And Approved Air/Flue Pipes - Room-Sealed; Description; Tested And Approved Air/Flue Pipes - Vaillant Flue pipe VKK SERIES Installation Manual

Flue pipe
Table of Contents

Advertisement

4
Tested and approved air/flue
pipes - room-sealed
This chapter describes the peripheral conditions under
which the ecoCRAFT condensing gas boilers can be fit-
ted to flue pipes supplied by the manufacturers shown
in Table 4.1.
4.1

Description

- with flue pipes checked and approved for the gas con-
densing boiler
- room-sealed operation
4.2

Tested and approved air/flue pipes

The exhaust gas systems used must be clearly and un-
ambiguously identifiable and must be in agreement with
one of the certificate numbers given in Table 4.1.
The layout and installation of the flue pipes must be in
accordance with the specification and installation manu-
als provided by the manufacturer of the exhaust gas
system. When the exhaust gas system is completely in-
stalled it must be marked with the prescribed identifica-
tion plate.
Flue pipes tested and approved for ecoCRAFT appli-
ances (GB)
Manufacturer
Material
Schiedel Rite
Stainless
Vent Ltd
steel
Table 4.1 Manufacturers of air/flue pipes (GB)
Installation manual flue pipe for ecoCRAFT 0020058722_02
Product
Certificate number
designation
DW - Alkon
0432 - BPR - 119938/2004
- EN 1856-2 T200 P1 W V2
Prima Plus
L50060 O200
- TUV 0036 CPD 9195 018
System-certifi ed fl ue pipe - open fl ued 4
Crowther Estate, Washington, Tyne & Wear NE 38 0AQ
Address
GB
Schiedel Rite Vent Ltd
Tel.: 0044 191 416 11 50
www.schiedel.co.uk