Fig. 4.31 Mounting the support plates (horizontal collector)
Fig. 4.32 Mounting the support plates (vertical collector)
Fig. 4.33 Mounting the support boards
Fig. 4.34 Mounting the ridge plates
Installation manual auroTHERM 0020057148_03
1
1
1
2
Installation 4
With roof angles of 22-75°
w
With horizontal collector position
• Mount the support plates above the collec-
tor:
- one on the external edge
(max. 150 mm from the edge)
- in the centre of the collector
(1066 mm from the edge).
• Make sure that the support plates are on
the collector frame slot (1).
• Fix the support plates to the roof batten
with two bolts no. 3 using the supplied
Torx bit.
With roof angles of 22-75°
s
With vertical collector position
• Mount the support plates above the collec-
tor:
- one on the external edge
(max. 150 mm from the edge)
- one per collector joint (central).
• Make sure that the support plates are on
the collector frame slot (1).
• Fix the support plates to the roof batten
with two bolts no. 3 using the supplied
Torx bit.
With roof angles of 22-75 °
• Slide the boards in the support plates.
• Fix the boards to the support plates with
two bolts no. 2 using the supplied Torx bit.
Note
h
The boards support the frames in
case of maintenance or snow load.
With roof angles of 22-75 °
• Slide the ridge plates on the support
plates (1).
• Make sure that the ridge plates are above
the side sections and slip in the corre-
sponding rail (2).
GB
21