Design Features Performance
THE ELECTRONIC TEMPERATURE CONTROLLER
The temperature controller is located in the top drawer. It consists of an LED display, two LED status indi-
cator lights and three touch pad buttons. The LED display shows the compartment temperature set point
and is calibrated in degrees Fahrenheit. The controller is factory programmed for a set point of 38°F for the
top drawer which will show when the unit is first powered up. The factory set point for the ice compart-
ment is 0°F.
To display the actual refrigerator compartment temperature, press the "WARMER" button momentarily.
A solid status indicator light (LED 1) will show the air temperature reading in the refrigerator drawer for
approximately 10 seconds.
To adjust the temperature set point, press the "SET TEMP" button momentarily; the display will flash. Press
the "WARMER" or "COOLER" button as desired to change the set point. When the desired set point shows
on the display, you can press the "SET TEMP" again or wait 10 seconds and the new set point will be
saved and the display will stop flashing. Wait 24 hours for the temperature to stabilize before checking the
actual temperature again. The compartment temperature range is 34°F to 45°F.
To check the actual temperatures via the display, touch and release the warmer button to view the
refrigerator (LED 1) temperature. Hold the colder button, while LED 1 is lit, the freezer (LED 2) temperature
will be displayed.
Continue holding the colder button, and the icemaker (LED 3) temperature will be displayed. If you
continue to hold the colder button, the display will cycle from freezer temperature to ice maker
temperature until the button is released.
Indicator light status
LED
Status
1
• Solid
• Flashing
2
• Solid
• Flashing
3
• Solid
1
2
WARMER
WARMER
COOLER
COOLER
• Compartment temperature displayed
• Not Applicable
• Freezer Temperature displayed
• Open Thermistor – call for service
• Icemaker temperature displayed
43
3
SET
SET
TEMP
TEMP