Electrical connection (non-Canada) - 3 wire cord

- ELECTRICAL SHOCK HAZARD - Failure
to disconnect power source before servicing could result in
personal injury or even death.
1.
Turn off power supply to outlet.
2.
Remove the screw securing the terminal block access
cover in the lower corner on the back of the dryer.
3.
Install a UL-approved strain relief according to the power
cord/strain relief manufacturer's instructions in the power
cord entry hole below the access panel. At this time, the
strain relief should be loosely in place.
4.
Thread an UNPLUGGED, UL-approved, 30 amp. power
cord, NEMA 10-30 type SRDT, through the strain relief.
5.
Attach the power cord neutral (center wire) conductor to
the SILVER colored center terminal on the terminal block.
Tighten the screw securely.
6.
Attach the remaining two power cord outer conductors
to the outer, BRASS colored terminals on the terminal
block. Tighten both screws securely.
- ELECTRICAL SHOCK HAZARD - Do not
make a sharp bend or crimp wiring/conductor at connections.
7.
Follow manufacturer's guidelines for fi rmly securing the
strain relief and power cord.
8.
Reinstall the terminal block cover.
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal ground from
the center terminal back to the GREEN screw next to the
terminal block.
3-wire receptacle
(NEMA type 10-30R)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
If a terminal screw falls during cord installation, it
can be retrieved in the terminal screw recovery slot below the
access panel.
DO NOT remove
DO NOT remove
internal ground in
internal ground in
a 3-wire system!!
a 3-wire system!!
11
Neutral
Neutral
(center wire)
(center wire)
Access cover
Access cover
screw
screw
Terminal
Terminal
block
block
Line 2
Line 2
(BRASS terminal)
(BRASS terminal)
Neutral
Neutral
(SILVER terminal)
(SILVER terminal)
Line 1
Line 1
(BRASS terminal)
(BRASS terminal)
Internal ground
Internal ground
(GREEN screw)
(GREEN screw)
Install
Install
UL-approved
UL-approved
strain relief here
strain relief here
Terminal screw
Terminal screw
recovery slot
recovery slot
Neutral
Neutral
terminal
terminal