To Disable Link Mode:
1) Press the PIP Link button to turn this mode OFF.
2) At this point, the mode is disabled. However, the PIP will not be cleared. This must be
manually done by using the CLEAR PIP key while holding a PIP # key.
NOTE: It is essential that the Output Resolution of the Linked destinations be the same. This is due to the
fact that all sizing and moving calculations are based on the output resolution. If the output resolutions
differ, PIP alignment across multiple screens will not appear to be correct.
Please make note of the following when adjusting the Horizontal or Vertical size of a PIP.
The scaler is limited to a maximum 2:1 compression. Therefore, the size of a full PIP ("full" meaning
the entire input image is displayed in the PIP) is limited by the following equations:
Min Horizontal Size (% of output image) = InputHSamples/(2 * OutputHRes) * 100
Min Vertical Size (% of output image) = InputVActive/(2 * OutputVRes) * 100
Note: InputH Samples may not be the same as input horizontal resolution due to over-sampling.
Example:
PIP source is standard video 710x485.
Output is XGA 1024x768.
Min Horizontal Size (%) = 710/(2 * 1024) * 100 = 34.67%
Min Vertical Size (%) = 485/(2 * 768) * 100 = 31.58%
PIP sizes smaller than the calculated limits can still be used. However the right and bottom edges of
the screen will be cropped.