Chassis Install Preparation
Check to be sure the wall sleeve, extension (if used), grille, and drain kit are installed properly before chassis
installation.
1. Remove.the.weatherboard.and.center.support.from.the.sleeve.(if.
still.in.place)..Be.sure.an.outdoor.grille.is.attached.
Figure 18
WEATHERBOARD
CENTER SUPPORT
NOTE:.
Use.a.wall.sleeve.adapter.kit.(PXSE).if.installing.a.P-Series.
chassis.in.a.T-Series.sleeve.
WARNING
Suffocation Hazards
Keep bag away from babies and children.
Do NOT use in cribs, beds or playpens.
Destroy immediately after opening. This bag
is NOT a toy.
Failure to do so can result in personal injury
and/or death.
2. Remove. the. front. cover. contained. in. a. protective. plastic. bag.
from. chassis.. . Remove. the. bag. and. dispose. of. it. properly.. .
.
If.the.control.door.is.not.installed,.follow.these.steps:
a..
From.the.front.cover,.slide.the.right.control.door.pin.into.the.
hole.on.the.right.side.of.the.front.cover.
b..
Slide.the.left.door.pin.into.the.hole.on.the.left.side.of.the.
front.cover.opening.
c..
Snap.cover.into.place.
16
NOTE:.
WALL SLEEVE
FRP015
IMPORTANT: .When.installing.a.Friedrich.PTAC.into.an.existing.sleeve,.
it.is.important.to.ensure.that.the.unit.is.installed.completely...Inspection.
of.the.air.seal.between.the.condenser.air.baffles.and.around.the.indoor.
mounting.flange.is.recommended.
In.some.cases.additional.gaskets.or.baffling.may.be.required.
To.avoid.breaking.the.door.or.hinge.pins,.do.not.apply.excessive.
force.when.installing.
Figure 19
INSERT PIN
IN THIS LOCATION
PIN
CONTROL
DOOR
FRP016