Table 45. Electrical data - high static motors - ½-5 tons (continued)
Total
Model
Unit
No.
Volts
FLA
018
220-240/50/1
19.7
018
265/60/1
9.2
018
265/60/1
16.6
018
380-415/50/3
5.2
018
380-415/50/3
7.0
024
208/60/1
14.9
024
208/60/1
17.8
024
230/60/1
14.9
024
230/60/1
19.5
024
220-240/50/1
12.7
024
220-240/50/1
24.0
024
265/60/1
11.1
024
265/60/1
21.5
024
208/60/3
9.2
024
208/60/3
10.6
024
230/60/3
9.8
024
230/60/3
12.1
024
380-415/50/3
5.2
024
380-415/50/3
8.5
024
460/60/3
4.6
024
460/60/3
7.6
030
208/60/1
16.2
030
208/60/1
21.8
030
230/60/1
16.2
030
230/60/1
23.8
030
220-240/50/1
19.5
030
220-240/50/1
29.9
030
265/60/1
12.7
030
265/60/1
26.4
030
208/60/3
11.0
030
208/60/3
13.5
030
230/60/3
11.0
030
230/60/3
14.7
030
380-415/50/3
7.5
030
380-415/50/3
10.8
030
460/60/3
5.2
030
460/60/3
9.2
WSHP-SVX01L-EN
Comp
Comp
RLA
LRA
No. of
Cmp
(ea)
(ea)
Comp.
MCC
GEHE/GEVE
9.6
54.0
1
15.0
7.7
35.0
1
10.8
7.7
35.0
1
10.8
4.2
28.0
1
6.5
3.6
28.0
1
5.6
12.8
58.3
1
20.0
12.8
58.3
1
20.0
12.8
58.3
1
20.0
12.8
58.3
1
20.0
11.2
60.0
1
17.5
11.2
60.0
1
17.5
9.6
54.0
1
15.0
9.6
54.0
1
15.0
7.7
53.7
1
12.0
7.7
53.7
1
12.0
7.7
53.7
1
12.0
7.7
53.7
1
12.0
4.2
28.0
1
6.5
4.2
28.0
1
6.5
3.6
28.0
1
5.6
3.6
28.0
1
5.6
14.1
73.0
1
22.0
14.1
73.0
1
22.0
14.1
73.0
1
22.0
14.1
73.0
1
22.0
16.7
79.0
1
26.0
13.5
72.0
1
21.0
11.2
60.0
1
17.5
11.2
60.0
1
17.5
8.9
58.0
1
13.9
8.9
58.0
1
13.9
8.9
58.0
1
13.9
8.9
58.0
1
13.9
5.8
38.0
1
9.0
5.8
38.0
1
9.0
4.2
28.0
1
6.5
4.2
28.0
1
6.5
Blower
Blower
Fan
Minimum
Motor
Motor
Motor
FLA
hp
Num.
Ampacity
1.53
1/3
1
1.53
1/3
1
1.53
1/3
1
0.95
1/3
1
0.95
1/3
1
2.10
1/3
1
2.10
1/3
1
2.10
1/3
1
2.10
1/3
1
1.53
1/3
1
1.53
1/3
1
1.53
1/3
1
1.53
1/3
1
1.53
1/3
1
1.53
1/3
1
2.10
1/3
1
2.10
1/3
1
0.95
1/3
1
0.95
1/3
1
0.95
1/3
1
0.95
1/3
1
2.10
1/3
1
2.10
1/3
1
2.10
1/3
1
2.10
1/3
1
2.77
1/2
1
2.77
1/2
1
1.53
1/3
1
1.53
1/3
1
2.10
1/3
1
2.10
1/3
1
2.10
1/3
1
2.10
1/3
1
1.70
1/2
1
1.70
1/2
1
0.95
1/3
1
0.95
1/3
1
Electrical Data
Maximum
Overcurrent
Electric
Circuit
Protective
Heat
Device
kW
24.57
25
4.4
11.16
15
0.0
20.78
25
4.0
6.20
15
0.0
8.75
15
4.4
18.10
30
0.0
22.22
30
3.3
18.10
30
0.0
24.36
30
4.0
15.53
25
0.0
30.04
35
5.4
13.53
20
0.0
26.91
30
5.3
11.16
15
0.0
13.22
15
3.3
11.73
15
0.0
15.18
20
4.0
6.20
15
0.0
10.58
15
5.4
5.45
15
0.0
9.50
15
5.3
19.73
30
0.0
27.26
30
4.1
19.73
30
0.0
29.80
30
5.0
23.65
40
0.0
37.42
40
6.5
15.53
25
0.0
33.04
35
6.6
13.23
20
0.0
16.85
20
4.1
13.23
20
0.0
18.31
20
5.0
8.95
15
0.0
13.46
15
6.5
6.20
15
0.0
11.54
15
6.6
Electric
Heat
Amps
18.1
0.0
15.1
0.0
6.1
0.0
15.7
0.0
17.4
0.0
22.5
0.0
20.0
0.0
9.0
0.0
10.0
0.0
7.5
0.0
6.7
0.0
19.7
0.0
21.7
0.0
27.2
0.0
24.9
0.0
11.4
0.0
12.6
0.0
9.1
0.0
8.3
73