To activate the door chime from an LCD Keypad:
Press [ ] to enter the function list, then scroll to find...
Press [ ] or [4] to enable or disable the Door Chime feature. Press [#] to return to the
Ready state.

Fire Alarm Operation

NOTE: The description below may not be applicable depending on how your installer has
programmed the fire alarm operations on your system. Ask your installer for more information
regarding your system's operation.
Alarm
During a fire alarm, the bell or siren will pulse ON and OFF. The transmission of the alarm to the
monitoring station is delayed for 30 seconds. If the alarm is not cleared within the 30-second delay, it will
be transmitted to the monitoring station.
Silence
To silence the bell or siren, press the [#] key. If the alarm is silenced and the smoke detector is not
reset, the alarm will resound after 90 seconds.
Resetting Smoke Detectors
Once the smoke detector is reset, if it still detects smoke, the alarm sequence will resound as described
above. If there is no smoke, the system will return to normal.
To reset smoke detectors from an LED or Fixed Message LCD5501Z keypad:
Press [ ][7][2].
To reset smoke detectors from an LCD Keypad:
Press [ ] to enter the function list. Scroll to find:
Press [ ] to select the output control. The display will read...
Use the arrow (< >) keys to find the following message and press the [ ] key to
select...
NOTE: If you suspect that a fire alarm has transmitted and that there is no fire condition, call the
monitoring station to avoid an unnecessary response. If a fire condition is apparent, follow your
evacuation plan immediately. If the alarm sounds at night, evacuate immediately.

Household Fire Safety Audit

Most fires occur in the home. To minimize this danger, we recommend that a household fire safety audit
is conducted and a fire escape plan is developed.
1. Are all electrical appliances and outlets in a safe condition? Check for frayed cords, overloaded
lighting circuits, etc. If you are uncertain about the condition of your electrical appliances or
household service, have a professional evaluate these units.
2. Are all flammable liquids stored safely in closed containers in a well-ventilated cool area? Cleaning
with flammable liquids should be avoided.
3. Are fire hazardous materials (matches) well out of reach of children?
4. Are furnaces and wood burning appliances properly installed, clean and in good working order?
Have a professional evaluate these appliances.
14
15
___________________________________________
16
___________________________________________
17
___________________________________________
18
___________________________________________
19
___________________________________________
20
___________________________________________
21
___________________________________________
22
___________________________________________
23
___________________________________________
24
___________________________________________
25
___________________________________________
26
___________________________________________
27
___________________________________________
28
___________________________________________
29
___________________________________________
30
___________________________________________
31
___________________________________________
32
___________________________________________
[F] FIRE __________________________________________
[A] AUXILIARY ____________________________________
[P] PANIC ________________________________________
The Exit Delay Time is ________ seconds.
The Entry Delay Time is ______ seconds.
For Service
Central Station Information:
Account #: ___________________________________
Installer Information:
Company: ___________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Telephone #: _________________________________
Telephone #: _________________________________
3

Advertisement

Table of Contents
loading

Table of Contents