Technical Data Manual Model Nos. and pricing : See Price List VITOCELL 100-VH/-BH Product may not be exactly as shown NCVA and NCVB Series Indirect-fired domestic hot water storage tank with one or two heat exchanger coils. With or without an optional electric heating element.
Product Information Vitocell 100-VH/-BH Technical Data Vitocell 100 Benefits at a glance: Standard Equipment Upright storage tank made of steel S235JR with one 79 USG (300 L) capacity Tank or two large surface bare-tube heat exchangers. DHW tank made from high-grade steel with fitted CFC free Glass-lined (enameled) tank in accordance with soft PU-foam thermal insulation.
Page 3
Product Information Vitocell 100-VH/-BH Technical Data Connections Legend H c in. NPT for safety valve A DCW connection I DHW connection B Solar - Return (lower coil) J Magnesium Anode or impressed-current anode C Sensor sleeve K Thermometer option D Solar - Supply (lower coil)
Specifications Vitocell 100-VH/-BH Technical Data Technical Data Model # Vitocell 100-VH Vitocell 100-VH Vitocell 100-BH Vitocell 100-BH NCVA NCVA NCVB NCVB Coil(s) Lower Lower Upper/Lower Upper/Lower Storage Capacity 79.2 79.2 Water Content Heating Circuit Water/Glycol content Solar Circuit 11.9 11.9 Tube Length (top) 24.9...
Page 5
Specifications Vitocell 100-VH/-BH Technical Data Technical Data (continued) For DHW production in conjunction with solar systems Suitable for heating systems with: and heating boilers, and heating systems without max. working pressure on heat exchanger side up to low limit for dual coil operation.
Page 6
Specifications Vitocell 100-VH/-BH Technical Data Technical Data (continued) For DHW production in conjunction with solar systems Suitable for heating systems with: and heating boilers, and heating systems without max. working pressure on heat exchanger side up to low limit for dual coil operation.
Page 7
Specifications Vitocell 100-VH/-BH Technical Data Flow Rate A Lower coil, 119 USG (450 L) capacity A 79 USG (300 L) B 79 USG (300 L) Lower coil and 119 USG B 119 USG (450 L) (450 L) Upper coil C 79 USG (300 L) Upper coil...
System Design Vitocell 100-VH/-BH Technical Data Installation Example Heating system connection Legend Spring-loaded flow check valve Discharge pipe Anti-scald tempering valve (field supplied) Shut-off valve Flow check valve Pressure reducing valve Drain DCW Cold water supply lines PGC Pressure gage connection Precharged expansion tank (required where backflow preventer is installed;...
Page 10
System Design Vitocell 100-VH/-BH Technical Data Installation Example (continued) Solar connection Legend Solar collector Vitocell 100 Filling valve Solar-Divicon (pumping station) Recirculating pump Anti-scald tempering valve Heating circuit Oil/Gas-fired boiler DCW Domestic cold water DHW Domestic hot water T&P Temperature and pressure relief valve...
DHW sensor connected to the auxiliary or emergency heating. It should be mounted in boiler control. a horizontal position by heating contractor. For solar heating systems, Viessmann recommends WARNING placement of the DHW tank temperature sensor in the solar collector return.
Page 12
5470 954 v1.1 Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper.