1 cfm = 0.47189 l/s
3
1 l/s = 3.6 m
2

TABLE OF CONTENTS

HRV(D) Series .................................................................................................. 3
HRV Series ...................................................................................................... 5
HRV-300D.................................................................................................... ...7
OPERATION............................................................................................................11
Modes Of Operation ........................................................................................11
Optional Remote Controls ................................................................................ 12
Digital Multi-Function Controls w/recirculation.....................................................12
Digital Multi-Function Controls .........................................................................13
INSTALLATION........................................................................................................14
Mounting the Unit .......................................................................................... 14
Location & Ducting .......................................................................................... 15
Examples ....................................................................................................... 18
Air Flow Balancing ......................................................................................... 22
MAINTENANCE ..................................................................................................... 24
TROUBLESHOOTING............................................................................................... 25
ELECTRICAL CONNECTIONS ................................................................................. 26
Sizing (Example) for maximum airflow normally required.
HRVs are typically sized to ventilate the whole house at a minimum of 0.35 air changes per
hour. To calculate, simply take the square footage of the house (including basement) and multi-
ply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by 0.35.
Example:
Maximum airflow required (CFM)
* Always consult your local code for sizing requirements in your area.
Alternate Method
Room classification
Master bedroom
Basement
Bedrooms
Living room
Others
Kitchen
Bathroom
Laundry room
Utility room
/hr
SQFT of House
1100
Basement
1100
Total SQFT
2200
Height of ceiling
x 8
Cubic volume
17600
/ 60
x 0.35
Number of rooms
CFM (L/s)
x 20 cfm (10 l/s)
if yes add 20 cfm / 10 l/s
yes or no
if no = 0
x 10 cfm (5 l/s)
x 10 cfm (5 l/s)
x 10 cfm (5 l/s)
x 10 cfm (5 l/s)
x 10 cfm (5 l/s)
x 10 cfm (5 l/s)
x 10 cfm (5 l/s)
Total Ventilation Requirements (add last column )
293
103
CFM Required
=
=
=
=
=
=
=
=
=
=