POWER USAGE

POWER USAGE REFERENCE GUIDE
WATT LEVELS
Application
Watts
Lighting:
Fluorescent Lamp
35
Light Bulb
40-100
Flood Lamp
500
Household Appliances:
Vacuum Cleaner
250-1200
Hot Water Service
2500-3500
Iron
900-1200
Kettle or Jug
1600-2400
Blender
300
Radio
60-200
Radiator
1000-2500
Refrigerator
200-500
Television Set
200-250
Toaster
750-1250
Electric Grill
1250
Electric Frying Pan
1150
Microwave
600-1000
Convection Oven
1500
Exhaust Fan
40
Washing Machine
500-3000
VCR
100
Slow Cooker
200
Freezer
700
Hairdryer
1000-1500
Fan Heater
3000
* Induction motors will require 3-5 times the rated
wattage at start-up.
23/05/2006
4:26 PM
Page 13
WATT LEVELS
Application
Watts
Power Tools:
Welder 140 amp
4000
9" Angle Grinder
2300
Palm Sander
175
Line Trimmer
350-1000
Jig Saw
400
Bench Grinder
400
Orbital Sander
450
Hedge Trimmer
500
4" Angle Grinder
550
1/3 HP Airless Sprayer
600
13mm Hammer Drill
600
Planer
700
5" Angle Grinder
750
Circular Saw
1000-2000
Router
1000-2000
Belt Sander
1000-2000
Cement Mixer
1320
Chain Saw 10"-16"
1500-2000
Hot Air Gun
1500
Air Compressor
2200
9" Grinder
2000
Pressure Washer
1500-2000
Other:
*Electric Induction
180
Motor ¼ hp
*Electric Induction
375
Motor ½ hp
*Electric Induction
750
Motor 1 hp
*Electric Induction
1500
Motor 2 hp
Note: Always consult the data plate on the tool
for specific electrical information.
13
MAINTENANCE

MAINTENANCE INSTRUCTIONS

Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.
Perform the service and inspection at the intervals shown in the Maintenance schedule below.
WARNING
Exhaust gas contains poisonous carbon monoxide. Shut off the engine before
performing any maintenance. If the engine must be run, make sure the area is well
ventilated.
NOTE: Use only genuine Talon parts as poor quality parts may damage the generator.
REGULAR SERVICE PERIOD (3) - Performed
at every indicated month or operating hour interval,
whichever comes first.
ITEM / PIECE / PARTE
ENGINE OIL
Check level
Change
AIR FILTER
Check
Clean
Replace
SPARK PLUG
Check-Adjust
Replace
SPARK ARRESTER
Clean
VALVE CLEARANCE
Check-Adjust
FUEL TANK AND STRAINER
Clean
FUEL LINE
Check
(Replace if necessary)
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized Talon generator dealer.
(3) For professional commercial use, log hours of operation to determine proper maintenance intervals.
Each First
Every 3
Every 6
Every Year
Use
Month or Months or Months or or 300Hrs
20Hrs(3) 50Hrs(3)
100Hrs(3) (3)
o
o
o
o
o(1)
o
o
o
o
o(2)
o(2)
Every 2 years (2)