TAblE OF CONTENTS

Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . 2
Principle of Operation . . . . . . . . . . . . . . . . . . . . . 2
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation Instructions . . . . . . . . . . . . . . . . . . . . 3

SAFETY INSTRUCTIONS

WARNING
120 volts may cause serious injury from electric
shock. Disconnect electrical power before servicing.
Sudden operation may cause personal injury or
property damage. Unplug the dehumidifier before
servicing.
Unit weight and dropping may cause personal injury
or equipment damage. Handle with care.
INSTAllER - PlEASE NOTE!
1. INSTAllATION MUST CONFORM TO All APPlICAblE STATE OR lOCAl CODES.
2. A 15 Amp circuit is required for proper operation of the dehumidifier. Do not use an
extension cord.
3. For protection of the compressor, unit must be transported and installed in an upright position.
If the unit was shipped or stored on its side, a 24 hour settling period is required before running the unit.

PRINCIPlE OF OPERATION

The purpose of the Aprilaire
®
Dehumidifier is to keep humidity in a space at acceptable limits, reducing
the unwanted effects of high humidity. The dehumidifier measures the condition of the air in the space
to determine when to run.
Do not use a dehumidifier to prevent window condensation in the winter. Indoor humidity levels must
typically get lower than what dehumidifiers can achieve during cold winter months. Use ventilation to
lower indoor humidity levels in the winter.

SPECIFICATIONS

Dimensions: 20
/
" W x 24" L x 20
/
"- 23
3
3
4
8
Weight: 93 lbs.
Capacity: 90 pints per day @ 275 CFM
(ANSI/AHAM DH-1-2003 80°F, 60% RH conditions)
Power: 115 VAC, 8 Amps, Unit is equipped
with an 8 ft. grounded cord.
2
Operating Instructions . . . . . . . . . . . . . . . . . . . . . 4
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . 5
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . 8
CAUTION
Do not use solvents/cleaners
on or near the control board.
Corrosive environments
can damage electrical
equipment. Do not use in pool
applications.
/
" H
Design Airflow: 275 CFM @ 0.6 in. w.c.
5
8
Filter: MERV 8, washable
Cabinet Insulation: 1" foil faced EPS insulation
Dehumidification Operating Conditions:
50°F-105°F, 40°F dew point minimum

INSTAllATION INSTRUCTIONS

1. Install the drain line
NOTE: The provided condensate trap must be installed to the dehumidifier.
IMPORTANT: Insert the high side of the trap into the drain outlet. The water flow direction is
shown on the trap and should point away from the dehumidifier (see Figure 1).
• I f there is not enough room to
install the trap directly into the
dehumidifier, use the provided 90°
elbow to position the trap close to
the dehumidifier.
• A fter verifying that the trap is in the
proper orientation, use PVC primer
and cement to secure the trap in
place. Cement the supplied threaded
90-1393
coupler to the outlet of the trap.
• S crew the supplied hose barb fitting into the coupler and attach the supplied
Route the hose to the nearest drain.
IMPORTANT: To prevent a pressure lock within the drain line, the tube MUST be installed with a
constant downward slope.
• P rime the drain system by filling the drip pan in the dehumidifier with water until flow is completed
to the drain (see Figure 2).
2. Plug the dehumidifier directly into an outlet.
DO NOT USE AN ExTENSION CORD.
NOTE: A 15 amp circuit is required for proper
operation.
3. Turn the ON/OFF switch to ON.
4. System Checkout:
• R otate the control knob clockwise to the
"Test" position.
a. The blower will start immediately and after
three minutes the compressor will start.
b. Both will run for one minute then both will
shut off.
c. Turn the control knob to the desired setting.
• I f the unit does not run, refer to the
Troubleshooting Guide.
FIGURE 1
BARBED FITTING
COUPLER
TRAP
1/2"
2-1/2"
/
inch I.D. drain hose.
1
2
FIGURE 2
EVAPORATOR
COIL
DRIP PAN
FILTER RAIL
90-1558